thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.2
GENERAL SAFETY
WARNING! Ensure Health & Safety, local authority, and general
workshop practice regulations are adhered to when using this
equipment. Under Health and Safety Law, Employers and Self
Employed Personnel have a legal duty to ensure Safe Working
Conditions for all employees and personel that may come into
contact with this equipment. In particular they must carry out a
specific risk and hazard assessment in the workplace to eliminate
or reduce any risk found and must record, update and retain
records of the results of this inspection.
familiarise yourself with the applications, limitations and any
possible or potential hazards of the tyre changer.
Maintain the tyre changer in good condition (use an authorised
service agent).
replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
WARNING! check regularly for damaged parts. Any part that is
damaged must be repaired or replaced before the equipment is
next used.
Locate the tyre changer in a suitable work area, keep area clean and
tidy and free from unrelated materials. Ensure that there is adequate
lighting.
WARNING! Use on a level surface, preferably concrete, to
which the tyre changer must be bolted.
Keep the tyre changer clean for best and safest performance.
Wear approved safety eye protection (standard spectacles are not
adequate).
3. SPECIFICATIONS
Max. safe Working Pressure. . . . . . . . . . . . n/A. . . . . . . . . . . . .150psi
Min. Wheel Diameter . . . . . . . . . . . . . . . 203mm. . . . . . . . . . . . 203mm
Max. Wheel Diameter . . . . . . . . . . . . . . 460mm. . . . . . . . . . . . 460mm
Min. Wheel Depth . . . . . . . . . . . . . . . . . . 40mm. . . . . . . . . . . . . 40mm
Max. Wheel Depth . . . . . . . . . . . . . . . . . 203mm. . . . . . . . . . . . 304mm
Working Height . . . . . . . . . . . . . . . . . . . 640mm. . . . . . . . . . . . 815mm
2. AIR SUPPLY - TC962 ONLY
2.1.
Ensure the air valve is in the "off" position before connecting to
the air supply.
2.2.
You will require an air pressure between 100 and 150psi.
2.3.
 WARNING! Ensure that the air supply is clean and does not
exceed 150psi. too high an air pressure and/or unclean air will
cause excessive wear and may cause damage and/or
personal injury.
2.4.
Drain the air tank daily. Water in the air line will damage the
tyre changer.
2.5.
clean the compressor air inlet filter screen weekly. the
recommended hook-up is shown below.
2.6.
Line pressure should be increased to compensate for
unusually long air hoses (over 8 metres). the minimum hose
diameter should be 10mm I.D. and fittings must have the same
inside dimensions.
2.7.
Keep hose away from heat, oil and sharp edges. check hoses
for wear and make certain that all connections are secure.
TC961
TC962
Original Language Version
InstructIons for:
WORKSHOP TYRE CHANGERS
TC961, TC962
MoDEL no's:
Keep hands and feet well clear of the bead breaker.
Maintain correct balance and footing. Ensure the floor is not
slippery and wear non-slip safety shoes.
remove ill fitting clothing. remove ties, watches, rings, and other
loose jewellery and contain and/or tie back long hair.
Keep children and unauthorised persons away from the work area.
DO NOT use the tyre changer for any purpose other than that for
which it is designed.
DO NOT operate the tyre changer if any parts are damaged or
missing as this may cause failure and/or personal injury.
DO NOT allow untrained persons to operate the tyre changer.
DO NOT stand on the tyre changer.
DO NOT operate the tyre changer when you are tired or under the
influence of alcohol, drugs or intoxicating medication.
MODEL TC962 ONLY
WARNING! Ensure correct air pressure is maintained and not
exceeded. recommended maximum pressure 150psi (10.3 bar).
WARNING! Disconnect the tyre changer from the air supply before
changing accessories, servicing or performing any maintenance.
Keep air hose away from heat, oil and sharp edges. check air
hose for wear before each use, and ensure that all connections
are secure.
DO NOT yank the hose from the air supply.
DO NOT direct air from the air hose at yourself or others.
When not in use ensure the air supply is turned off.
TC962
TC961
tc961, tc962
Issue: 2 - 20/10/09

Advertisement

loading

Summary of Contents for Sealey TC961

  • Page 1 TC961, TC962 MoDEL no's: thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 5 Alloy Wheels. If tyres are to be changed on aluminium wheels the optional tyre bar, sealey model no. TC963, must be used to prevent damage to the wheel rims (see fig.5b). use a rim sheild to protect the wheel finish when levering a bead over the wheel rim.
  • Page 3 WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, www.sealey.co.uk...
  • Page 4 Hose, Air, ram tc963 tyre Bar, Aluminium Wheels not supplied with tyre changer 363/483 seal Kit, ram tc963 tyre Bar, Aluminium Wheels Version no: Date Issued: 180701 Sole UK Distributor, Sealey Group, Bury st. Edmunds, suffolk. E-mail: sales@sealey.co.uk 01284 757500 01284 703534...

This manual is also suitable for:

Tc962