Epson WF-7620/7610/7110 Series
Inside the USB Cover (ADF Unit/Cables related to Scanner Unit (WF-7620/WF-7610 Series)
•ADF motor cable
•Scanner Motor cable
•ADF PE sensor cable
•ADF document sensor cable
•ADF plunger cable
•ADF encoder sensor cable
•Scanner Open Sensor cable
•Paper Support Encoder Sensor cable
Space between Housing
Upper and Main Board
Ferrite core A
Frame Base 1st
For the correspondence between the cables, FFCs and the connectors on the Main Board, see
When routing the Scanner motor cable (CN32), ADF document sensor cable (CN72), ADF encoder sensor cable (CN73), Paper Support Encoder Sensor
cable (CN76), follow the procedure below.
Insert the cables from the hole A on the Housing Upper and route them through the hook B, rib A (x2), and rib B (x3) on the Frame Base 1st, then route
them inside the rib C and connect them to their connectors on the Main Board.
Set the ferrite core A of the Scanner Motor cable as shown above.
Route the ADF motor cable (CN33), ADF PE sensor cable (CN71), ADF Plunger cable (CN77), and Scanner Open Sensor cable (CN74) as shown below.
Insert the cables from the hole A on the Housing Upper and route them through the hook A and the slit on the Frame Base 1st, then connect them to their
connectors on the Main Board.
Set the ferrite core B of the ADF Motor cable as shown above.
Insert the Grounding Wires (x3) from the hole A on the Housing Upper, and secure them at the position shown above with the screw.
Route the Scanner FFC as follows.
1. Insert it into the hole B of the Housing Upper, and route under the rib D of the Housing Upper.
1. Thread the Scanner FFC through the ferrite core C, and secure the ferrite core C to the position shown above with double-sided tape.
2. Secure the Scanner FFC on the position shown above with double-side tape, and then connect the FFC to the connector (CN70) on the Main Board.
Put the excess portion of the cables after routing into the space between the Housing Upper and Main Board.
Disassembly/Reassembly
Upper: Before ADF/Scanner Unit is installed
Hole A
Grounding
Rib D
Scanner FFC
Wire
メ イ ン基板
Ferrite core B
Slit
C.B.S-TITE SCREW 3x6 F/ZN-3C (6±1 kgf
"Main Board Unit (2)
(p49)".
Hole B
Wrap three times.
Housing Upper
Ferrite core C
Main Board Unit
Route the cables and FFC to the Housing Front Assy as follows.
Panel Grounding Wire
Wrap it around the point shown above three times and route it along the shape of Housing Front Assy, then secure it on the Main Board Unit with the screw.
Cover Open Sensor cable
Route it along the shape of Housing Front Assy, then connect it to the connector (CN53) on the Main Board Unit.
Panel FFC
Route it along the rear of the Housing Front Assy and pull it out from the hole, then secure the FFC and the ferrite core to the position shown above with
double-sided tape.
Panel Unit's bottom(WF-7620/WF-7610 Series)
Panel Unit's bottom
Relay cable
Hook A
Panel FFC
Hook B
Rib A
Rib B
Rib C
Rib D
Double-sided tape
·
cm)
Ferrite core
Speaker cable
C.B.P-TITE SCREW 3x10 F/ZN-3C (6±1 kgf
Route the cables and FFCs on the bottom of the Panel Unit as follows.
Panel Grounding Wire
Secure on the Panel Board with the screw.
Speaker Cable
Connect to the Relay cable.
Panel FFC
Set the ferrite cores (x2) in the positions shown above and secure the FFC
with double-sided tape, then connect it to the connector (CN20) on the
Panel Board.
Routing FFCs/cables
Housing Front Assy (WF-7620/WF-7610 Series)
Housing Front Assy
Panel Grounding Wire
Cover Open Sensor cable
Panel FFC
Ferrite core
Hole
Standard line
Double-sided tape
·
C.B.S-TITE SCREW 3x6 F/ZN-3C (8±1 kgf
cm)
FAX Unit (WF-7620/WF-7610 Series)
FAX Unit
Panel Grounding Wire
Panel Board
Double-sided tape
·
cm)
Secure the ferrite core to the position shown above with double-sided tape.
Thread the FAX FFC through the ferrite core and route it according to its
folds and connect it to the connector (CN5) on the Main Board, then
secure it to the position shown above with double-sided tape (x2).
Revision B
Rear
Hole
Panel FFC
Align with standard line
and secure with tape.
Ferrite core
Main Board
FAX FFC
Double-sided tape