Download Print this page

Toro 119-1100 Installation Instructions Manual page 3

Wired controller kit for pro force debris blower

Advertisement

Installing the Wired Controller
For Debris Blowers with Serial Numbers
310000001 to 311000001
1. Disconnect the battery cables from the battery.
Note: Disconnect the negative-battery cable first, and
then disconnect the positive-battery cable.
2. Disconnect the wire-harness leads from the
wireless-control base
3. Plug the appropriate wired-controller harness lead into
the appropriate wire-harness lead that was previously
disconnected from the wireless-control base
3
and
Figure
4).
1
g018907
1. Pink wire from the adapter
2. Wire-harness lead
to wireless-controller
harness
(Figure
1).
(Figure
2
3
Figure 3
3. Wire-harness lead to the
wire controller
1. Connect this wire-harness
lead to the wired-controller
harness.
2. Wireless-control base wire
harness
3. Wireless-control base
4. Connect this wire-harness
lead to the wire-harness
adapter.
4. Plug the appropriate lead from the harness adapter
into the remaining wireless-control base wire-harness
lead that was previously disconnected from the
wireless-control base
5. Plug the other wired-controller-harness lead into the
appropriate wire-harness-adapter lead
Figure
4).
6. Plug the remaining controller wire into the pink wire
from the harness adapter
7. Connect the positive-battery cable first, and then
connect the negative-battery cable.
3
Figure 4
5. Wire-harness adapter
6. Wired controller
7. Yellow wire from the
wired-controller harness
(Figure
3).
(Figure 3
(Figure 3
and
Figure
and
4).

Advertisement