DB19
DBX26.1
OK (job list selection from PLC, status)
Edge evaluation: no
Signal state 1 or
Transfer correctly completed
edge change 0 → 1
Signal state 0 or
Transfer completed with error
edge change 1 → 0
Corresponding to ....
Valid for HMI Advanced
DB19
DBX26.2
Error (job list selection from PLC, status) (previously bit 0)
Edge evaluation: no
Signal state 1 or
Transfer completed with error
edge change 0 → 1
Signal state 0 or
Transfer correctly completed
edge change 1 → 0
Corresponding to ....
Valid for HMI Advanced
DB19
DBX26.3
Active (job list selection from PLC, status)
Edge evaluation: no
Signal state 1 or
Job in progress
edge change 0 → 1
Signal state 0 or
No task in progress
edge change 1 → 0
Corresponding to ....
Valid for HMI Advanced
DB19
DBX26.5
Unload (job list selection from PLC, status)
Edge evaluation: no
Signal state 1 or
Unload active
edge change 0 → 1
Signal state 0 or
Unloading inactive
edge change 1 → 0
Corresponding to ....
Valid for HMI Advanced
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
2.1 Various interface signals and functions (A2)
Detailed Description