Detailed description
2.12 Block descriptions
Signal
OldToolMag
OldToolLoc
Status
Ready
Error
Pulse diagram
(1)
(2)
(3)
(4)
(5)
(6)
192
Type Type
I
INT
I
INT
I
INT
A
BOOL
A
INT
Activation of function by means of a positive edge
Positive acknowledgment: Tool management has been transferred
Reset function activation after receipt of acknowledgment
Signal change using FC
This signal chart is not permissible. The job must generally be terminated since the new tool
positions must be conveyed to the tool management in the NCK.
Negative acknowledgment: Error has occurred, error code in the output parameter "Error".
Value range
Remark
-1, 0..
Current magazine number of new tool
-1: Tool remains at its location OldToolLoc =
any value.
Only permissible if TaskIdent = 2
Max. location
Current location number of tool to be replaced
number
1...7, 103...105
Status information about transfer operation
1= transfer completed
0..65535
Error checkback
0: No error has occurred
1: Unknown "TaskIdent"
2: Unknown "TaskIdentNo"
3: Illegal task
("signal "Interface (SS) active" of selected
revolver = "FALSE")
Other values:
The number corresponds to the error message
of the tool management function in the NCK
caused by this transfer.
Basic logic functions: PLC Basic program powerline (P3 pl)