Detailed description
2.12 Block descriptions
PI service: CONFIG
Function Reconfiguration:
The reconfiguration command activates machine data, which have been entered sequentially
by the operator or the PLC, almost in parallel.
The command can only be activated when the control is in RESET state or the program is
interrupted (NC stop at block limit). An FB 4 error checkback message is output if these
conditions are not fulfilled (state = 3).
Parameterization
Signal
PIService
Unit
WVar1
PI service: DIGION
Function Digitalize On:
Selecting digitizing in the specified channel.
Parameterization
Signal
PIService
Unit
PI service: DIGIOF
Function Digitalize Off:
Deactivating digitizing in the specified channel.
Parameterization
Signal
PIService
Unit
130
Type
ANY
INT
INT
Type
ANY
INT
Type
ANY
INT
Basic logic functions: PLC Basic program powerline (P3 pl)
Value range
PI.CONFIG
1
1
Value range
PI.DIGION
1 to 10
Value range
PI.DIGIOF
1 to 10
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Meaning
Reconfiguration
Classification
Meaning
Digitizing on
Channel
Meaning
Digitizing off
Channel