10-31: Networking Keep Alive Setup (Ot) - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program 10 : System Configuration Setup
Level:
IN
Description
Use Program 10-31: Networking Keep Alive Setup to set the interval and retry
count of the AspireNet networking keep alive message. The keep alive is used for
ISDN and IP networking.
The keep alive message is automatically responded to by the destination SV8100, if
the response is not received the retry count will start. If a response is not received
within the number of retries the networking link will be taken out of service. When the
link is taken out of service:
Input Data
Item
No.
Programming Manual

10-31: Networking Keep Alive Setup (OT)

Any calls that are in progress will be released.
Park Hold orbits will be released.
No further Park Hold information will be sent until the link is active.
The link will automatically become active when the next keep alive response is
received.
01
Keep Alive Interval
This program is used to set the interval of Keep Alive. The
SV8100 does not send Keep alive when this item is set to "0".
If this entry is greater than "0", network PRI spans which are
using Kentrox DSUs will not re-sync when removed from service
then returned to service.
02
Keep Alive Retry Timer
Set how many times the SV8100 resents Keep Alive.
Item
Issue 10.1
Input Data
Default
0
0-65535
1-255
5
2 - 53