Input Data
Item
No.
Programming Manual
Item
21
Signal limiter
Set the Signal Limiter Mode.
Not used by IPLB.
22
Echo Canceller NLP Mode
Non-linear processing mode.
Enable this option to decrease the low
level echo. When NLP is enabled, the
voice with low level is replaced with
NLP noise. As a result, a low echo of
the level is usually removed compared
with the conversation level.
Not used by IPLB. Echo canceller
setup is 84-31 for IPLB.
24
Echo Canceller NLP Noise Setting
Becomes invalid item if 84-12-22 is set
to Disabled.
Set the noise level adjusting method
added with NLP.
When "0" is set, the level is self-
adjusted - when "1" is set, Program 84-
01-27 is used.
Not used by IPLB. Echo canceller
setup is 84-31 for IPLB.
26
TX (Transmit) Gain
Define the setting to amplify and to
attenuate the size of the transmission
voice. The gain given when the voice
packet is sent from the VOIPDB is set.
Not used by IPLB. Echo canceller
setup is 84-31 for IPLB.
Input Data
1
= Mode0
2
= Mode1
3
= Mode2
4
= Mode3
5
= Mode4
6
= Mode5
1. There is no limitation.
2. The limitation is the maximum.
3. Limitation size
4. It is limiting it.
5. Limitation smallness
6. The limitation is minimum.
0
= 2 wire & 4 wire
1
= 2 wire only
(2-wire means analog and 4-wire
means digital).
0
= adaptive
1
= fixed
0-40 (-20 ~ +20)
0 = -20 dbm
1 = -19 dbm
:
20 = 0 dbm
:
39 = 19 dbm
40 = 20 dbm
Issue 10.1
Default
6
1
0
20 (0 dbm)
2 - 791