Nokia 7368 ISAM ONT BGW320-505 Product Manual page 39

Intelligent services access manager
Hide thumbs Also See for 7368 ISAM ONT BGW320-505:
Table of Contents

Advertisement

7368 ISAM ONT BGW320-505 Product Guide
5
6
7
8
9
10
11
12
Issue: 01
Release 06.02.00b | October 2019 | Edition 01
Connect the fiber optic cable with an SFP adapter into the SFP+ connector; see Figure
the location of the SFP connector.
Danger — Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5 in.
(3.8 cm) when connecting the fiber optic cable. Too small of a bend radius
in the cable can result in damage to the optic fiber.
Note — Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC fiber
optic pigtail cable.
Install the power supply according to manufacturer specifications.
Note — Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12VDC, 4A.
Power up the ONT unit by inserting the power cable.
If applicable, use the WPS button to connect additional Wi-FI devices to the ONT.
Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and
Cabling Installation Guide.
Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
If necessary, reset the ONT.
i
Locate the Reset button on a BGW320-505 indoor ONT as shown in Figure 5.
ii
Press the Reset button for less than 10 seconds to reboot the ONT.
Press the Reset button for 10 seconds to reset the ONT to its factory defaults.
STOP. This procedure is complete.
3FE-47753-AAAA-TCZZA
Install an BGW320-505 indoor ONT
5
for
39