64
01
(*1) The grid pattern of about 1cm square is outputted.
Data are always made for A3 size. If printing is made on paper smaller than A3, the remaining data are
not outputted. (Images are not formed on the drum.)
(Initial window)
Ready to copy.
S
100%
8 1/2×11
1
7SEG LED
65
10
Key ACK time setting display/non-display setting
Used to set Enable/Disable of the key ACK time setting in the system settings. When this setting is set to
Enable (1), the key ACK time is displayed in the system settings, allowing setting.
Sim65-10 KEY TIME
1:KEY ACK TIME
[
0- 1]
[CA] key: Exit the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
11
Info lamp setting
Used to set the Info lamp brightness (PWM duty) and the kind of flashing.
Sim65-11 INFO LAMP
1:PWM DUTY
2:BLINK TYPE
[
1- 5]
During this simulation, Info lamp is lighted to allow checking of the brightness.
[CA] key: Exit the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
66
01
FAX soft SW setting
Used to display the FAX-related soft SW on the LCD and set and change the soft SW setting with numeric
keys input.
[OK] Key or
[START] Key
After completion of printing one sheet
Display: Setting
0: Disable
1
1: Enable
1
Lamp brightness
1: 100%
1
2: 80%
1
3: 60%
4: 40%
1
5: 20%
Kind of flashing
1: Flashing
2: Flashing 10 times, and lighting thereafter.
3: Lighting
Sim66-1 FAX SOFT SW
ENTER FAX SOFT SW.#
( 3DIGITS )
XXX
[OK] key
XXX is the input value of the soft SW number.
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric keys
: Soft SW input
bit No. input
[OK] key
: Settlement of the input value
[START] key
: Settlement of the input value
[C] key
: Input number clear for soft SW number input,
disable for the following windows
MX-M182 SIMULATIONS 7-51
Contents
Copies in progress.
S
100%
8 1/2×11
Sim66-1 FAX SOFT SW
No.XXX
XXXXXXXX
USE # KEY 12345678
[OK] key
To the initial window of SIM66-1
Sim66-1 FAX SOFT SW
No.XXX
XXXXXXXX
3sec later
Remark
Default:
1
Default:
Lamp brightness: 1