10%. AS 4032.1 WMKA25301 installation compliance *Enware products are to be installed in accordance mesh) is recommended. A Pressure reduction valve may with the Plumbing Code of Australia (PCA), AS/NZS3500 be required to comply with recommended maximum and the manufacturer’s instructions.
Face Plate Bracket In-Wall Box Front Cover ATMS600 Aquablend SQX Cartridge Replacement (5 Year Service) Fixing Base Ring for Front Plate Fixing Screws for Mixer Body Mixer Body Spacer Spirit Level In-Wall Box ATMS613 Indicator Kit www.enware.com.au Call 1300 369 273...
90 degrees, check for leaks. IMAGE 7 If leaking refer to Troubleshooting Section on page 25 for possible causes and rectification or contact Enware. 8. While the mixer is running, rotate handle in a clockwise motion and test water temperature from the outlet to ensure the water temperature changes with the motion of the handle.
11. The wall is ready to be sheeted. Make sure sheeting is finished hard up against the protruding section of box. Box cut-out size: 166 mm wide x 222 mm high Call 1300 369 273 www.enware.com.au...
Page 11
19, and complete commissioning report on page 26. Extra Components Supplied: • 1x Large Plug for Body (in place of SQX Thermostatic Cartridge during servicing) • 2x Small Plugs for inlets (in place check valve strainer assemblies during servicing) www.enware.com.au Call 1300 369 273...
The sleeve is free to spin right around. See IMAGE 18 and 19 10. On the main mixer body, place rubber washers inside IMAGE 19 IMAGE 20 fixing nuts as shown (if not installed already) IMAGE 20. Call 1300 369 273 www.enware.com.au...
Page 13
See IMAGE 26 and 27 17. The SQX Thermostatic mixer is now ready for commissioning. Follow the testing and commissioning procedure on page 19. IMAGE 24 IMAGE 25 SLOT IMAGE 26 IMAGE 27 www.enware.com.au Call 1300 369 273...
Page 14
If handle is loose or rocks after this process, remove handle and repeat steps 1-4 above again after you have wound the up Spline connector enough so it provides a tight fit with IMAGE 30 IMAGE 31 the Handle Locking pin. Call 1300 369 273 www.enware.com.au...
Page 15
(35-46°C) TEMPERATURE OF MIXED WATER INCREASES HANDLE REACH IS 200mm R 200mm MAXIMUM FLOW RATE IS REACHED - CONTINUED TURNING ADJUSTS TEMPERATURE FLOW VOLUME INCREASES TURN HANDLE TO ACTIVATE AMBIENT (COLD) WATER FLOW IMAGE 34 www.enware.com.au Call 1300 369 273...
The ENWARE AQUABLEND SQX Thermostatic Mixers are supplied factory set at a maximum of 41ºC +/- 2ºC. To alter this temperature adopt the following procedure: Note: Changing the maximum set temperature will change the amount of rotation of the handle. Increasing the temperature will mean extra rotation, while decreasing the temperature will result in less rotation.
IMAGE 46 6. Test operation and check for leaks. If leaks occur around the spout, loosen off M5 grub screw slightly. IMAGE 45 IMAGE 46 www.enware.com.au Call 1300 369 273...
Page 18
10. Thread on the Swivel spout locking nut until it comes to rest against the spout and secure in position by tightening the 2 x M3 grub screws. 11. Assemble the handle and test operation for leaks. IMAGE 51 IMAGE 52 IMAGE 53 IMAGE 54 Call 1300 369 273 www.enware.com.au...
The ENWARE AQUABLEND SQX Thermostatic Mixing Valve will only require minimal preventative maintenance work to ensure it operates at its optimum level of performance. The valve should be commissioned and serviced annually, unless the installed conditions dictate more frequent servicing is necessary.
SHUT DOWN TEST IN-SERVICE TESTING Once the correct outlet temperature has been achieved, Enware Australia recommends that Thermostatic the valve’s internal mechanism should be exercised at Mixing Valves have monthly temperature checks and least 3 times by alternately shutting off the hot and cold adjustments as needed during the life of the valves.
Page 21
4. Using a long M5 allen key unwind the internal basin mount fixing screw found in lower cavity of the mixer. Once loose carefully lift basin spout off basin Hob. IMAGES 60 and 61 IMAGE 60 IMAGE 61 www.enware.com.au Call 1300 369 273...
Ensure all O-rings are slightly greased handle anti clockwise and check operation and flow. before re-fitting basin body. 12. Commence commissioning as per instructions on page 19. Ensure fittings are wound down flat against hob mount Call 1300 369 273 www.enware.com.au...
Page 23
5. Re-fit strainer/check valve assembly ensuring the O-rings have been lightly greased and then fit Strainer covers. Turn on water supplies and test for leaks. Commence IMAGE 69 commissioning as stated on page 19. www.enware.com.au Call 1300 369 273...
• Replace cartridge Water comes on when • Mixer has been installed incorrectly or • Re-install or replace cartridge. Refer to service handle is in closed not tightened to a firm stop. instructions on page 21 position Call 1300 369 273 www.enware.com.au...
Australia Effective 1 September 2014 exceptions Enware Australia Pty Limited (ACN 003 988 314) (“we” or “us”) warrants that this product (also referred to as “our goods”) will be free from all This warranty does not apply in respect of any...
1. The local water supply 2. The valve manufacturer 3. The Australian Standards authority /supplier requirements for Plumbing and Drainage YES NO YES NO YES NO If NO, give details and action taken: Call 1300 369 273 www.enware.com.au...
Page 27
Contractor Lic/Cert No Contractor Name (please print) Licensed Plumber (Signature) Date Contractors Phone No Owner/Occupier Signature Date A duplicate copy of this report is to be retained at the site for any inspection by authorised persons www.enware.com.au Call 1300 369 273...