Nokia 7368 Product Manual page 74

Intelligent services access manager ont
Hide thumbs Also See for 7368:
Table of Contents

Advertisement

Replace a G-240W-J indoor ONT
74
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at the
P-OLT using TL1 or a network manager. If the old SLID is used, no changes
need to be made at the P-OLT; see the operations and maintenance documentation
for the OLT for more details.
Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and
17
Cabling Installation Guide.
Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
18
If necessary, reset the ONT.
19
Locate the Reset button; see Figure 17.
i
Insert the end of a straightened paper clip or other narrow object into the hole in the
ii
Reset button to reset the ONT.
STOP. This procedure is complete.
20
3FE-48009-AAAA-TCZZA