Decommissioning; Preparing For Decommissioning; Decommissioning Process - Bosch Rexroth CytroPac Operating Instructions Manual

Hydraulic power unit
Hide thumbs Also See for Rexroth CytroPac:
Table of Contents

Advertisement

Overall machinery/system

11 Decommissioning

11.1 Preparing for decommissioning

Provide collecting containers that are large enough to accommodate the total
volume of the hydraulic fluid.
The total volume of the hydraulic system comprises the volumes of the oil tank,
the line system, the drives, etc.
Always observe applicable instructions for the overall machinery/system.
Unless these operating instructions provide different information, proceed as
follows:
– Prevent any hazards due to machinery in the vicinity.
– Unauthorized personnel must not be allowed access to the working area.
– Lower and securely support all loads.

11.2 Decommissioning process

Switch off the power supply and secure the system against restarting.
Switch off the hydraulic pressure supply and secure it.
Make sure that all relevant system parts are depressurized and de-energized.
Disconnect the hydraulic fluid draining hose using the clip, refer to fig. 1, pos. 10,
and drain the hydraulic fluid into the provided collecting container.
In this connection, ensure complete draining of the lines and actuators. If
necessary, carry out bleeding measures.
Decommission the overall machinery/system as described in the overall machinery/
system operating instructions.
Decommissioning