Issue: 01
Release 06.01.01 | June 2019 | Edition 09
This equipment is ESD sensitive. Proper ESD
Warning 1 —
protection must be used when entering the TELCO Access
portion of the ONU.
ANSI-specific: If using cable other than the
Warning 2 —
recommended brands, select only UL-listed cable, rated for the
specific installation.
The communications grounding electrode must
Warning 3 —
be separated from lightning conductors as specified in 800.53
and at least 6 ft (1.8 m) from electrodes of other systems.
Steam or hot water pipes or air terminal conductors
(lightning-rod conductors) shall not be employed as electrodes
for protectors.
Earthing and bonding of the outdoor ONU must
Note 1 —
comply with the ETSI-specific requirements found in local
electrical wiring codes.
Observe all local and national laws and regulations
Note 2 —
that may be applicable to this installation.
3FE-46261-AAAA-TCZZA
Grounding safety
95