Content of the complete acceptance test
Documentation
Documentation of the machine and of safety functions
1. Machine description (with overview)
2. Specification of the controller (if this exists)
3. Configuration diagram
4. Function table
5. SI functions for each drive
6. Information about safety equipment
Function test Part 1
General function test, including a check of the wiring/programming
1. Test of shutdown paths
2. Test of the SS1 and SS2 stop functions
3. Test the forced dormant error detection of the inputs and outputs
4. Test of the emergency stop function and of safety circuits
5. Changeover test of SI functions
Function test Part 2
Detailed function test and valuation of SI functions used.
1. Test of the SI function "Safe Operational Stop" (SOS)
2. Test of the SI function "Safely Limited Speed" (SLS)
3. Test of the SI function "Safe Speed Monitor" (SSM)
Conclusion of the report
Report of the commissioning status tested and countersignatures
1. Inspection of SI parameters
2. Logging of checksums (for each drive)
3. Assigning and logging the Safety password
4. RAM to ROM backup and upload of project data to the STARTER and backup of the
5. Countersignature
Safety Integrated
Function Manual, (FHS) , 07/2007 Edition, 6SL3097-2AR00-0BP0
Active monitoring functions depending on the operating mode, the protective doors and
other sensors. This table should reflect the objective or results of project engineering.
(Test of forced dormant error detection at the inputs and outputs)
(only if a TM54F module is used)
(with evaluated measurement diagram or measured values)
(with evaluated measurement diagram or measured values)
(with evaluated measurement diagram or measured values)
(do not disclose in the report!)
project
Acceptance test and acceptance report
8.1 General information