Siemens SINUMERIK 840Di Diagnostic Manual page 341

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
17224
Channel %1 block %2 tool T/D= %3 - tool type %4 is not permitted
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Incorrect T no. / D no.
%4 = Incorrect tool type
Definitions:
On this system, it is not possible to select tool offsets of the
indicated tool types.
The variety of tool types can both be limited by the machine OEM
and be reduced on individual control models.
Only use tools of the tool types permitted for this system.
Check whether an error has occurred on defining the tool.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program or correct the tool data
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17230
Channel %1 block %2 Duplo no. already assigned
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If an attempt is made to write a tool Duplo number to the name of which another tool (another T
number) already exists with the same Duplo number.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17240
Channel %1 block %2 illegal tool definition
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If an attempt is made to modify a tool data that would subsequently damage the data consistency or
lead to a conflicting definition, this alarm will appear.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17250
Channel %1 block %2 illegal magazine definition
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If an attempt is made to modify a magazine data that would subsequently damage the data
consistency or lead to a conflicting definition, this alarm will appear.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-341

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents