Siemens SINUMERIK 840Di Diagnostic Manual page 277

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
15910
Channel %1 block %2 touch probe not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Measure without deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAW (measure
without distance-to-go). The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
are allowed, whether the probe is actually connected or not.
Example:
N10 MEAW=2 G01 X100 Y200 Z300 F1000
Probe 2 without deletion of distance-to-go
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Include a probe number within the limits given above in the keyword MEAW=... This must correspond
to the hardware connection of the probe.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
15950
Channel %1 block %2 no traverse motion programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Measure with deletion of distance-to-go
In the part program, no axis or a traversing path of zero has been programmed with the command
MEAS (measure with deletion of distance-to-go).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and add the axis address or the traversing path to the measurements block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
15960
Channel %1 block %2 no traverse motion programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Measure without deletion of distance-to-go
In the part program, no axis or a traversing path of zero has been programmed with the command
MEAW (measure without deletion of distance-to-go).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and add the axis address or the traversing path to the measurements block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-277

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents