FL1 Installation
(continued)
CONNECT THE OBDII/HEAVY DUTY HARNESS
Install the OBDII or 6/9 pin Deutsch cable connector to
•
the Vehicle diagnostic connector
Mount the female in the factory receptacle and the 16 pin
•
into the FL1.
CONNECT THE PTO INPUT (WHEN APPLICABLE):
Connect the positive blue wire in the device harness to
•
the PTO trigger's output wire
MOUNTING THE DRIVER ID READER (WHEN
APPLICABLE):
Drill a 3/8" hole in the location on the dash where the
•
driver ID reader will be mounted
Feed the wires from the driver ID reader through the 3/8"
•
hole and push the reader in
Secure the reader from the back side using the supplied
•
push-washer
Connect the driver ID reader to the harness directly
•
using the provided plugin.
OBD-II Wire Diagram:
5C360 Wire Diagram:
3MM PITCH
24 PIN MALE
CONNECTOR
1
13
P1
12 24
16
8
5C734M-2 Rev A
9
1
1
P3
3MM PITCH
5 PIN FEMALE CONNECTOR
5
3MM PITCH
1
24 PIN MALE
3MM PITCH
P4
SERIAL 2
6 PIN FEMALE CONNECTOR
CONNECTOR
6
3
3MM PITCH
P5
3 PIN MALE CONNECTOR
1
3
1
3MM PITCH
P6
4 PIN FEMALE CONNECTOR
4
2
1
3MM PITCH
P7
3 PIN FEMALE CONNECTOR
3
1
P8
3MM PITCH
12
2 PIN FEMALE CONNECTOR
2
P9
OPEN WIRES
LED Verification
LED Status
1
Unassigned Blue
2
Comm
3
VBUS
4
GPS
NOTE: LED 1 is unassigned. Please ignore.
JPOD Wire Diagram:
RED
BLACK
Pin
Color
WHITE
1
Blue
P1:
13
White
19
Green
1
13
21
Yellow
22
Black
24
23
Red
©2018 Spireon, Inc. All rights reserved.
Color Behavior
N/A
Orange Solid - Connected
Blinking - Searching
Red
Solid - On
Green
Solid - GPS Fix
Blinking - GPS Time
Sync
16
5C732M-2 Rev A
9
Function
PTO Input (Positive)
Ignition (Positive)
Negative Output for
Starter Disable
Negative Output for Door
Unlock
Ground
12v Constant
8
1
Need help?
Do you have a question about the FleetLocate FL1 and is the answer not in the manual?