- Click "[READ] From BMD B'd" button to check that the changed parameters have been written correctly.

Figure 3-147: Rack BMS Config Setting window

Important
- "CAN ID" of the first rack is 0x2001. This value depends on the order of the rack from the
system BMS.
- To set the second Rack BMS, enter "0x2002" under 'Write Value' for the second rack BMS.
- To read and configure the Rack BMS after setting the CAN ID, the correct CAN ID setting must
be selected from the drop-down menu.
- "Module BMS counter per 1 Rack" is the number of modules connected to the Rack BMS. Its
range is 1–32. For example, in case of 136S Rack, the value is 17; and in case of 128S Rack, the
value is 16.
7. If multiple racks are installed, repeat 3.10.12.2 Rack BMS Configuration for each rack.