Measurement made easy Introduction For more information — AWT210 This Communications Supplement provides Further publications for the AWT210 transmitter are 2-Wire transmitter procedures specifically related to the AWT210 available for free download from: PROFIBUS PA® 2-wire transmitter. Refer to the www.abb.com/measurement...
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A Health & Safety Document symbols Potential safety hazards AWT210 transmitter – electrical Symbols that appear in this document are explained below: DANGER – SERIOUS DAMAGE TO HEALTH WARNING – BODILY INJURY...
Direct current supply only. ABB is committed to ensuring that the risk of any environmental damage or pollution caused by any of This symbol, when noted on a product enclosure or its products is minimized as far as possible.
The AWT210 transmitter meets the requirements of PROFIBUS PA Application profile 3.02. ABB Ltd and its affiliates are not liable for damages and/or losses related to such security breaches, any unauthorized Using the PROFIBUS protocol, devices from different...
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A 5 Transmitter functionality and 4 Device overview operator interface controls Four variants of AWT210 are available for use with pH, ORP, pION, and conductivity sensors. Process interface Sensor Input Channels Supported sensors: •...
The quiescent current value is used as a reference to establish the number of devices that can be installed on a single bus line. DP/PA link Slave level Profibus-PA AWT210 2-wire transmitter Figure 1 Typical PROFIBUS network...
Impedance 135 to 165 Ω Property damage Capacitance per unit length <30 pf/m When connecting an AWT210 to a PROFIBUS-PA network: Loop resistance 110 Ω/km • Use cable that meets PROFIBUS specifications for Core diameter 0.64 mm reliable communications Core cross section >0.34 mm...
3.02 Integration using GSD PROFIBUS devices differ with respect to available functionality The GSD file for AWT210 transmitters specifies the device and parameters for each device type and manufacturer. In order specific Ident No. 3404 and conforms to the PROFIBUS...
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A 8 PROFIBUS slots Physical block –...
Page 11
OctetString n+58 DIAGNOSIS_EXT_MASK Simple OctetString n+59 ASSEMBLY_DATE Simple OctetString n+60 SAVINGS Simple Unsigned8 n+61 SERVICES Simple Unsigned8 n+62 to n+64 NULL// ABB Reserved n+65 PASSWORD Simple VisibleString n+66 ADDRESS Record PRIVATE_ADDRESS n+67 DATA Record PRIVATE_DATA PRIVATE_MEMORY_ n+68 MEMORY_ADDRESS Record ADDRESS...
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A …8 PROFIBUS slots pH Transducer block –...
Page 13
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A Index Parameter Access...
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A …8 PROFIBUS slots 2-electrode conductivity transducer block –...
Page 15
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A Index Parameter Access...
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A …8 PROFIBUS slots Toroidal conductivity transducer block –...
Page 17
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A Index Parameter Access...
Page 18
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A …8 PROFIBUS slots 4-electrode conductivity transducer block –...
Page 19
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A Index Parameter Access...
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A …8 PROFIBUS slots Analog input blocks –...
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A 9 Device tables Table 1 Software write locking table...
Page 22
Table 32 4-electrode conductivity sensor group US Tech Sensor Group A Sensor Group B Table 26 Auto Cal Buffer Values ABB 4.01 pH ABB 7.00 pH ABB 9.18 pH MERCK 4.00 pH MERCK 7.00 pH MERCK 9.00 pH MERCK 10.00 pH DIN 1.68 pH...
Page 23
AW T 2 1 0 P R O F I B U S PA 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ P R O F I B U S - E N R E V. A Acknowledgements •...
Page 24
We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.