Dini Argeo DFWPM Series User Manual

Dini Argeo DFWPM Series User Manual

Portable repeater

Advertisement

DFWPM SERIES
Portable repeater
ENGLISH
USER MANUAL – v4
www.diniargeo.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DFWPM Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Dini Argeo DFWPM Series

  • Page 1 DFWPM SERIES Portable repeater ENGLISH USER MANUAL – v4 www.diniargeo.com...
  • Page 3: Table Of Contents

    INDEX OF FUNCTIONS INTRODUCTION WARNINGS General warnings CHARACTERISTICS Technical features General functions Powered by a rechargeable battery HOW TO USE IT PC power supply via a USB connector Switching the system on Switching the system off How to identify the weighing scale displayed by the DFWPM (in multiple weighing scale systems) How to repeat the single weighing scale or display the total weight Calculating the tare in sum mode The display...
  • Page 4: Introduction

    INTRODUCTION The purpose of this manual is to inform the use about the various operating modes, the features of the keys and the indications on the display of the “DFWPM” series portable wireless repeater. Utmost attention was paid when drafting this manual; however, we appreciate anyone pointing out to us any unintentional errors or inaccuracies.
  • Page 5: Warnings

    WARNINGS General warnings The instrument is covered by a warranty and MUST NOT BE OPENED BY THE USER for any reason whatsoever. Any attempt to repair or modify the unit may expose the user to an electric shock hazard and will void any warranty condition. Any issue with the unit or the system must be reported to the manufacturer or the retailer from which it was purchased.
  • Page 6: Characteristics

    CHARACTERISTICS Technical features Power supply rechargeable internal battery Full charge time 8h (with original charger, supplied) Operating time about 40 hours Operating temperature -10...+40°C Wireless communication type radio frequency Communication frequency 868MHz Antenna built-in Display 25 mm backlit LCD display with adjustable intensity Keypad waterproof mechanical keypad with 5 buttons Casing...
  • Page 7: How To Use It

    HOW TO USE IT PC power supply via a USB connector The DFWPM “USB” version can be used both as a mobile unit or as a fixed unit, permanently connected to the PC via a USB port. The DFWPM “USB” can indeed be powered directly through the PC’s USB port and run as an RF/USB conversion module: 50.00 The power supply via the USB port excludes charging via a battery.
  • Page 8: Switching The System On

    HOW TO USE IT Switching the system on Single weighing scale system 1. Switching on the weighing scale 2. Switching on the DFWPM 50.00 DFWPM connects itself automatically and displays the weight. Multiple weighing scale system 1. Turn on all the weighing scales 2.
  • Page 9: Switching The System Off

    HOW TO USE IT Switching the system off 1. Switch off each weighing scale individually 2. Switch off DFWPM by pressing and holding down key C for a long time. When DFWPM shows the message “ECo N”, it can be turned off by pressing and holding down key C. How to identify the weighing scale displayed by the DFWPM (in multiple weighing scale systems) icons light up individually to repeatedly the weighing scales repeatedly or turn on at the same time to indicate that the displayed weight is a sum.
  • Page 10: The Display

    HOW TO USE IT Features of the DFWPM keypad The following table shows the keys repeated by the DFWPM, depending on the connected weighing scale: TYPE OF WEIGHING SCALE DFWPM 3590 keypad CPWE keypad DGT keypad DFW keypad ZERO ZERO ZERO ZERO TARE...
  • Page 11: Dfwpm "Usb" Version

    DFWPM “USB” VERSION The “USB” version allows you to save weighing operations in real time and download them on a PC via USB port for subsequent processing. The memory can contain up to 500 weighing operations for internal-use applications or 250 weighing operations in the version type-approved for relationships with third parties (with Alibi memory).
  • Page 12: Specific Functions For The Dfwpm "Usb" Version

    SPECIFIC FUNCTIONS FOR THE DFWPM “USB” VERSION How to save a weighing operation If the MASTER is showing the sum, the total weight will be saved. How to calculate the total weight of the weighing operations performed and save it You can save the total weight of the weighing operations carried out and save it by proceeding as follows: b.
  • Page 13: Managing The List Of Weighing Operations With The Weighconsole Software

    MANAGING THE LIST OF WEIGHING OPERATIONS WITH THE WEIGHCONSOLE SOFTWARE Download the list of weighing operations on a PC 1. Launch the Dini Argeo “WeighConsole” software. 2. Enter the “download weighing operations” mode pC.wait pC.Conn The display shows “pc.wait” until When the connection has been com- pleted, the display shows “pc.Conn”.
  • Page 14: Saving The List Of Weighing Operations

    MANAGING THE LIST OF WEIGHING OPERATIONS WITH THE WEIGHCONSOLE SOFTWARE Saving the list of weighing operations The list can be saved by pressing the “Save List” key. The list is available as a .csv or a .xls file. EXAMPLE: .csv file The Alibi memory ID number appears only if the Alibi memory option is in place.
  • Page 15: End The Communication Between The Dfwpm "Usb" And The Pc

    MANAGING THE LIST OF WEIGHING OPERATIONS WITH THE WEIGHCONSOLE SOFTWARE End the communication between the DFWPM “USB” and the PC. 1. Exit the “download weighing operations” mode 2500.0 DFWPM “USB” reconnects itself to the available weighing scales and displays the weight. 2.
  • Page 16: Messages Of The Instrument During Use

    MESSAGES OF THE INSTRUMENT DURING USE MESSAGE DESCRIPTION Displayed for a moment if the master is able to connect to the slave X; if the connection eco.x is not possible, the message remains fixed and the master emits a beeping signal. MeM.xxx Displayed for a moment when the weight is saved.
  • Page 17 NOTES DFWPM USER_MAN_ENG_DFWPM_v4...
  • Page 18 NOTES This publication, or any part of it, cannot be reproduced without the Manufacturer’s written authorisation.All the information reported in this manual is based on data available at the time of publication. The Manufacturer reserves the right to make changes to its products at any time, without prior notice and without incurring in any penalty.
  • Page 19 DFWPM USER_MAN_ENG_DFWPM_v4...
  • Page 20 Authorised assistance centre stamp HEAD OFFICE Via Della Fisica, 20 41042 Spezzano di Fiorano, Modena - Italy Tel. +39.0536 843418 - Fax. +39.0536 843521 info@diniargeo.com SERVICE ASSISTANCE Via Dell’Elettronica, 15 41042 Spezzano di Fiorano, Modena - Italy Tel. +39.0536 921784 - Fax. +39.0536 926654 service@diniargeo.com...

Table of Contents