INDEX OF FUNCTIONS INTRODUCTION WARNINGS General warnings CHARACTERISTICS Technical features General functions Powered by a rechargeable battery HOW TO USE IT PC power supply via a USB connector Switching the system on Switching the system off How to identify the weighing scale displayed by the DFWPM (in multiple weighing scale systems) How to repeat the single weighing scale or display the total weight Calculating the tare in sum mode The display...
INTRODUCTION The purpose of this manual is to inform the use about the various operating modes, the features of the keys and the indications on the display of the “DFWPM” series portable wireless repeater. Utmost attention was paid when drafting this manual; however, we appreciate anyone pointing out to us any unintentional errors or inaccuracies.
WARNINGS General warnings The instrument is covered by a warranty and MUST NOT BE OPENED BY THE USER for any reason whatsoever. Any attempt to repair or modify the unit may expose the user to an electric shock hazard and will void any warranty condition. Any issue with the unit or the system must be reported to the manufacturer or the retailer from which it was purchased.
CHARACTERISTICS Technical features Power supply rechargeable internal battery Full charge time 8h (with original charger, supplied) Operating time about 40 hours Operating temperature -10...+40°C Wireless communication type radio frequency Communication frequency 868MHz Antenna built-in Display 25 mm backlit LCD display with adjustable intensity Keypad waterproof mechanical keypad with 5 buttons Casing...
HOW TO USE IT PC power supply via a USB connector The DFWPM “USB” version can be used both as a mobile unit or as a fixed unit, permanently connected to the PC via a USB port. The DFWPM “USB” can indeed be powered directly through the PC’s USB port and run as an RF/USB conversion module: 50.00 The power supply via the USB port excludes charging via a battery.
HOW TO USE IT Switching the system on Single weighing scale system 1. Switching on the weighing scale 2. Switching on the DFWPM 50.00 DFWPM connects itself automatically and displays the weight. Multiple weighing scale system 1. Turn on all the weighing scales 2.
HOW TO USE IT Switching the system off 1. Switch off each weighing scale individually 2. Switch off DFWPM by pressing and holding down key C for a long time. When DFWPM shows the message “ECo N”, it can be turned off by pressing and holding down key C. How to identify the weighing scale displayed by the DFWPM (in multiple weighing scale systems) icons light up individually to repeatedly the weighing scales repeatedly or turn on at the same time to indicate that the displayed weight is a sum.
HOW TO USE IT Features of the DFWPM keypad The following table shows the keys repeated by the DFWPM, depending on the connected weighing scale: TYPE OF WEIGHING SCALE DFWPM 3590 keypad CPWE keypad DGT keypad DFW keypad ZERO ZERO ZERO ZERO TARE...
DFWPM “USB” VERSION The “USB” version allows you to save weighing operations in real time and download them on a PC via USB port for subsequent processing. The memory can contain up to 500 weighing operations for internal-use applications or 250 weighing operations in the version type-approved for relationships with third parties (with Alibi memory).
SPECIFIC FUNCTIONS FOR THE DFWPM “USB” VERSION How to save a weighing operation If the MASTER is showing the sum, the total weight will be saved. How to calculate the total weight of the weighing operations performed and save it You can save the total weight of the weighing operations carried out and save it by proceeding as follows: b.
MANAGING THE LIST OF WEIGHING OPERATIONS WITH THE WEIGHCONSOLE SOFTWARE Download the list of weighing operations on a PC 1. Launch the Dini Argeo “WeighConsole” software. 2. Enter the “download weighing operations” mode pC.wait pC.Conn The display shows “pc.wait” until When the connection has been com- pleted, the display shows “pc.Conn”.
MANAGING THE LIST OF WEIGHING OPERATIONS WITH THE WEIGHCONSOLE SOFTWARE Saving the list of weighing operations The list can be saved by pressing the “Save List” key. The list is available as a .csv or a .xls file. EXAMPLE: .csv file The Alibi memory ID number appears only if the Alibi memory option is in place.
MANAGING THE LIST OF WEIGHING OPERATIONS WITH THE WEIGHCONSOLE SOFTWARE End the communication between the DFWPM “USB” and the PC. 1. Exit the “download weighing operations” mode 2500.0 DFWPM “USB” reconnects itself to the available weighing scales and displays the weight. 2.
MESSAGES OF THE INSTRUMENT DURING USE MESSAGE DESCRIPTION Displayed for a moment if the master is able to connect to the slave X; if the connection eco.x is not possible, the message remains fixed and the master emits a beeping signal. MeM.xxx Displayed for a moment when the weight is saved.
Page 18
NOTES This publication, or any part of it, cannot be reproduced without the Manufacturer’s written authorisation.All the information reported in this manual is based on data available at the time of publication. The Manufacturer reserves the right to make changes to its products at any time, without prior notice and without incurring in any penalty.
Need help?
Do you have a question about the DFWPM Series and is the answer not in the manual?
Questions and answers