USER MANUAL
WEIGHT INDICATOR
E-BATCH1: SOFTWARE FOR SINGLE PRODUCT DOSAGE
SYSTEMS, IN LOADING OR UNLOADING
3590EXP, 3590EXT, CPWE, CPWET, CPWETF series indicator
E-BATCH1_01_13.05_EN_U

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3590EXP Series and is the answer not in the manual?

Questions and answers

osama
January 23, 2025

please we ask for weighing software

Summary of Contents for Dini Argeo 3590EXP Series

  • Page 1 USER MANUAL WEIGHT INDICATOR E-BATCH1: SOFTWARE FOR SINGLE PRODUCT DOSAGE SYSTEMS, IN LOADING OR UNLOADING 3590EXP, 3590EXT, CPWE, CPWET, CPWETF series indicator E-BATCH1_01_13.05_EN_U...
  • Page 2: Table Of Contents

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U INDEX 1. INTRODUCTION ................................. 4 2. MAIN TECHNICAL SPECIFICATIONS ..........................5 2.1 ACCESSORIES AVAILABLE ............................6 2.2 SYMBOLS ..................................6 3. INSTALLATION .................................. 7 3.1 CPWE DRILLING TEMPLATE, CASE AND DIMENSIONS ..................7 3.2 CPWET CASE AND DIMENSIONS..........................
  • Page 3 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 11.5 CANCELLATION OF A FORMULA IN THE DATABASE ..................35 11.6 PRINTING OF FORMULAS IN THE DATABASE ..................... 35 11.7 ALPHABETICAL RESEARCH ..........................36 12. DATABASE ACCESS PASSWORD ..........................36 13. FUNCTIONING OF THE MONOCOMPONENT DOSAGE ....................36 13.1 DOSAGE MODE ..............................
  • Page 4: Introduction

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 1. INTRODUCTION This manual was created to help you install and learn all about the functional possibilities of the purchased indicator. The instrument is suitable for use in various weighing environments. Not only does it have all the normal features of high-precision scales, but it also gives you the possibility to work in specific environments due to the functioning modes contained in the software implemented in the FLASH MEMORY on the internal board;...
  • Page 5: Main Technical Specifications

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 2. MAIN TECHNICAL SPECIFICATIONS 3590E: - 12 Vdc ( 8 ÷ 24 Vdc in the IO versions), with internal 100 ÷ 240 Vac (50÷60 Hz) / 12 Vdc power adapter. - 6 Vdc from rechargeable built-in battery, fitted depending on the model. CPWE: - 8 ÷...
  • Page 6: Accessories Available

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 2.1 ACCESSORIES AVAILABLE On the indicator is possible to implement internal and external modules used to increase interfacing possibilities. For example, the number of usable outputs, various types of printers, in order to have a report of the weighs made, or giant display in order to better see the weigh operations Also, one can connect a PC in order to simply program the instrument through Dinitools ™, or in order to have a complete management of the weighs.
  • Page 7: Installation

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 3. INSTALLATION 3.1 CPWE DRILLING TEMPLATE, CASE AND DIMENSIONS The weight indicator has an anodized aluminium case, whose external dimensions are shown in the figure 1. It should be mounted on a panel board respecting the safety norms. DRILLING TEMPLATE DIMENSION: 187,5mm x 91,5mm Figure 1...
  • Page 8: Cpwet Case And Dimensions

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 3.2 CPWET CASE AND DIMENSIONS The weight indicator has an STAINLESS STEEL case, whose external dimensions are shown in the figure 2. The instrument may be installed on the wall. NOTE: If the identification plate is supplied separately (therefore not attached to the indicator), it is advisable to attach it to the indicator, in order to be able to identify the instrument.
  • Page 9: Cpwetf Case And Dimensions

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 3.3 CPWETF CASE AND DIMENSIONS The weight indicator has a STAINLESS STEEL case, whose external dimensions are shown in figure 3. The instrument may be installed on the wall. NOTE: If the identification plate is supplied separately (therefore not attached to the indicator), it is advisable to attach it to the indicator, in order to be able to identify the instrument.
  • Page 10: 3590E Case And Dimensions

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 3.4 3590E CASE AND DIMENSIONS ABS MODEL The indicator has an IP65 ABS case, whose external dimensions are shown in the Figure 4. It can be simply put on a table or fixed to a shelf or column available on request. NOTE: If the identification plate is supplied separately (therefore not attached to the indicator), it is advisable to attach it to the indicator, in order to be able to identify the instrument.
  • Page 11 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U STAINLESS STEEL MODEL The indicator has an STAINLESS STEEL case, whose external dimensions are shown in the Figure 5. It can be simply put on a table or fixed to a shelf or column available on request. NOTE: If the identification plate is supplied separately (therefore not attached to the indicator), it is advisable to attach it to the indicator, in order to be able to identify the instrument.
  • Page 12: Power Supply

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 3.5 POWER SUPPLY - The 3590E indicator is powered with 12Vdc voltage (8 ÷ 36 Vdc in the I/O version), through an internal adapter which ÷ converts the 100 240Vac, 50÷60Hz mains voltage, and 6 Vdc, from the built-in battery(fitted depending on the model). TO POWER the instrument through the 240 Vac mains, or TO RECHARGE the battery, insert the plug and the adapter to the 240 Vac mains socket.
  • Page 13: Turning Off The Instrument

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 3.7 TURNING OFF THE INSTRUMENT TO TURN OFF the 3590E/CPWET/CPWETF or TO RESTART the CPWE keep the C key pressed until the “- OFF -“ message appears on the LED display and “ *** POWER OFF *** ” on the LCD display. TO TURN OFF CPWE: Remove the instrument’s power supply.
  • Page 14 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U CPWE: CPWET/CPWETF:...
  • Page 15: Function Of The Keys

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 4.1 FUNCTION OF THE KEYS In the following section, and later on in the manual, the keys’ functioning is described in accordance to how these are configured in the factory. It is possible to customise the functionality of the keys through the << F.KEYS >> step. FUNCTION - If pressed for an instant, it clears the tare value.
  • Page 16: 2Ndf" Key: Second Function Of The Keys

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U - If pressed for an instant, it executes the printing and the zeroing of the general total. - In the numeric or alphanumeric input phase, it selects the digit to be modified from left to right.
  • Page 17: Entering Alphanumeric Text

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 4.1.2 ENTERING ALPHANUMERIC TEXT It might be necessary, while the weighing system is working, to enter some alphanumerical texts such as descriptions, alphanumerical messages (operator, number of lot, customer, etc.). To enter the characters one uses the 0 to 9 keys. By pressing one of these keys a few times, the characters shown on the key will be shown on the display: initially the first letter in the bottom left will appear, and then the other characters towards the right.
  • Page 18: Help Menu

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 4.1.4 HELP MENU By pressing at length the HELP key it is possible to access a menu containing the list of keys with the relative function, and status (locked or unlocked) indication. The display shows: F1:301 ...
  • Page 19: Display Functions

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 4.2. DISPLAY FUNCTIONS While weighing, the display is subdivided mainly in 4 sections, shown in the figure below: 1) WEIGHT. 2) STATUS INDICATORS (led pilot lights / or graphic symbols), see section “STATUS INDICATOR” 3) SELECTABLE INFO (one line in the 3590E;...
  • Page 20: Weight Zoom

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U FORMULA DESCRIPTION T 3.000kg FASAUT 3590E displays NOTE: If the EEEEE message appears, this means that the value exceeds the maximum number of digits shown by the instrument. 4.2.1 WEIGHT ZOOM The zoom function allows to increase the size of the weight digits, in order to ease the reading from a distance; with the active zoom, only the second line info is shown (see section “DISPLAYED DATA”).
  • Page 21: Status Indicators

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 4.2.2 STATUS INDICATORS FUNCTION (3590 Model) Indicates the type of indicator power supply: red pilot light: through built-in power adapter; POWER green pilot light: through battery (charged battery); pilot light off: through battery (discharged battery). Indicates that the weight detected by the weighing system is near zero, including the interval of 1/4 +1/4 of 0...
  • Page 22 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U GRAPHIC SYMBOL SYMBOL ON THE LCD FUNCTION DISPLAY The weight detected by the weighing system is near zero, included within the interval of – 1/4 and +1/4 of the scale division. The weight is unstable. The displayed weight is a GROSS WEIGHT (depending on the software language).
  • Page 23: Battery Level Indication

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 4.2.3 BATTERY LEVEL INDICATION The indicator is able to recognise whether it is powered by mains or by battery, and indicate its charge level; to enable the battery level indication, one should configure the << bt.LEVEL >> step. The charge level is shown during weighing with the battery symbol.
  • Page 24: Displayed Data

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 4.2.4 DISPLAYED DATA Some data shown on the display can be modified by selecting one of the various visualisations provided for by the indicator. CPWE/CPWET/CPWETF: The selectable info are shown on two lines under the “weight” section. It is possible to modify independently the visualization of both lines.
  • Page 25 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U SELECTION OF THE SECOND LINE INFO By pressing in sequence the 2ndF and F9 keys, one will change the second line info, scrolling in order the following visualisations: WITH SELECTED FORMULA OR WITHOUT SELECTED FORMULA NUM.
  • Page 26 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 3590E The selectable info are shown in the first line of the LCD display; by pressing in sequence the 2nd F and F10 keys, one scrolls in order the following visualisations: WITH SELECTED FORMULA OR WITHOUT SELECTED FORMULA NUM.
  • Page 27: System Status Info

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 4.2.5 SYSTEM STATUS INFO MESSAGE DESCRIPTION The instrument is ready to dose WAIT FOR START The instrument, at the start of the dosage, has detected the weight as unstable. Give a START INSTABILITY ERR. impulse to exit the error status.
  • Page 28 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U AT START-UP MESSAGE DESCRIPTION Err – 37 The converter points are less than the instrument’s internal divisions; one must execute a alternated with no.CAL TECHNICAL DEFAULT (dFLt.t parameter of the SET-UP environment) and carefully carry out the calibration.
  • Page 29: Scale Selection

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 5. SCALE SELECTION If various scales are connected, in order to select these, press the 2ndF key and then a numeric key from 1 to 4: 2ndF and 1 >> Selection of scale number 1. 2ndF and 2 >>...
  • Page 30: Tare Functions

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 7. TARE FUNCTIONS 7.1 SEMIAUTOMATIC TARE To tare any weight which is on the scale one should: - press the TARE key. The display shows “tArE” for an instant, and then 0 (net weight); furthermore, also the relative indicators are enabled. The display shows therfore the gross weight value and the stored tare value.
  • Page 31: Limitation Of The Tare Functions

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 7.6 LIMITATION OF THE TARE FUNCTIONS For specific requirements, it is possible to limit the functions of the tare with approved instrument; by setting “YES” in the SEtuP >> d.SALE step. the SEMIAUTOMATIC TARE can not be modified with a manual or calculated tare. the manual or calculated tare must be entered or modified only with an UNLOADED scale.
  • Page 32: Display Of Metric Data (Info)

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 9. DISPLAY OF METRIC DATA (inFO) The indicator is fitted with a function named “INFO”, thanks to which it is possible to view the configuration metric data: First range capacity, first range division. Second range capacity, second range division.
  • Page 33: Formulas Database

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 11. FORMULAS DATABASE PREMISE: by formula we mean the set of parameters which allow dosing the material in the desired mode. The indicator has a database in which it is possible to store up to 500 formulas having one description of 16 characters; each formula is linked to a storage number, from 0 to 499.
  • Page 34: Unloading Dosage

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 13) Enter the MAXIMUM tare value which will be on the scale in order to give the START impulse. NOTE: 0  MAX TARE  MAX. WEIGHT 14) Enter the setpoint 1 value (the entry of this parameter is not requested by default). 15) Enter the setpoint 2 value (the entry of this parameter is not requested by default).
  • Page 35: Selection Through 4 External Inputs

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 11.2.2 SELECTION THROUGH 4 EXTERNAL INPUTS To select a formula stored in database one should enable the four inputs in combination among these, recalling a specific memory storage number depending on the combination. In the following table there are the possible combinations of the inputs and the recalled memory storage number.
  • Page 36: Alphabetical Research

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 11.7 ALPHABETICAL RESEARCH 1) Press the F1 to access the database. 2) Press the F4 key: enter the desired characters to search in the description of all the formulas. 3) Select the desired storage in the list of the results by using the arrow keys   and press ENTER. 4) Carry out one of the operations described in the previous sections.
  • Page 37 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U FASAUT indicates that the material is being dosed at the maximum speed; this abbreviation remains until a weight value is reached in which the SLOW WEIGHT + FLIGHT WEIGHT is missing from the FINAL WEIGHT. At this point the SLOAUT abbreviation is displayed indicating the end of the fast dosage and the beginning of the slow dosage.
  • Page 38: Manual Dosage Of A Product In Loading

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U The instrument: d. starts to dose at maximum speed (approximate dosage). e. once the WEIGHT TO BE DOSED – FLIGHT WEIGHT – SLOW WEIGHT (in other words 10,000 - 0,100 - 1,500 = 8,400kg) is reached, it slows down the dosage speed (fine dosage).
  • Page 39: Functioning With Control Light

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U f. Once the WEIGHT TO BE DOSED – SLOW WEIGHT (in other words 10,000 - 1,500 = 8,500kg) is reached, the instrument turns off the quick dosage light (approximate) and maintains active only the slow dosage light (fine dosage);...
  • Page 40: Unloading Dosage

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 13.1.3. UNLOADING DOSAGE a) Dosage start With the system in the status of “WAITING FOR START”, by giving a START impulse , the indicator before enabling the dosage, checks that the signal coming from the scale’s load cell is stable., or in any case, becomes stable within the time set in the MAX.
  • Page 41: Unloading Dosage Phase

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U - If the weight of the dosed material is not within the set tolerance, the "ERR. TOLL" error is indicated; the R8 and R9 relays are enabled and the system goes into the pause status. At this point the LED display shows the weight;...
  • Page 42: Formula Execution Modes

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U The instrument: executes the dosage in the WAIT START condition when the START button is pressed, it checks that the weight is ≥ REFILL START WEIGHT + FORMULA TARGET (in other words 2,500kg) - If the weight is the same or greater than this threshold, the new dosage can start.
  • Page 43: Start Dosage Cycle

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U By supplying the dosage start to the system, the following takes place - the verification of the correct tare presence and the weight stability - the automatic tare of all the connected platforms The instrument executes the first formula (See section “DOSAGE MODE”...
  • Page 44: Pause - Momentary Interruption Of The Dosage Cycle

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 13.3.3 PAUSE – MOMENTARY INTERRUPTION OF THE DOSAGE CYCLE To pause the dosage press for an instant the PAUSE button or F10 key. By carrying out this operation all the instrument’s outputs are disabled and the DOSAGE PAUSE message appears on the display. To exit this PAUSE condition press the START button.
  • Page 45: Maximum Dosage Time

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U DESCRIPTION OF THE FUNCTION: The display will show the number of executed cycle repetitions, which will increase at the end of each complete cycle, and the number of cycles to be executed. Nr. of CYCLES 0 .
  • Page 46: No Test Tolerance Of Weight

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U EXAMPLE With formula Tolerance Percentage Weight = 10%, one will have the following tolerance ranges: - with target = 100 kg  Tolerance weight = +/- 10kg, therefore: TARGET-TOL. % WEIGHT TARGET TARGET+TOL. % WEIGHT 90 kg (target -10%) 100 kg 110 kg (target +10%)
  • Page 47: Volume Counter

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U SETTING THE PRODUCTION PROGRAM Through function 318 combinable with the desired key (<< F.KEYS >> step, TECH.MAN.REF.), one is asked first to input the number of formulas, from 1 to 4: press the enter key, input the number and confirm with enter. After this one is asked to select the formula position using the arrow keys ...
  • Page 48 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U SIMPLE PRINTOUT - Programmable printout - Through the PRINT F5 key one prints the linked format: With the APPROVED instrument: the printing works if there is a NET WEIGHT of at least 20 divisions. the printout is re-enabled depending on how the <<...
  • Page 49 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U GENERAL TOTAL - Programmable printout - By pressing the F9 key the GENERAL TOTAL is reset and the linked format is printed. PRINTING OF THE DATABASE - Fixed printout - By pressing the “F5” key inside the databases it is possible to print a report of the FORMULAS DATABASE. REPORT OF A SPECIFIC FORMULA - Fixed printout - Through function 303, combinable with the desired key (<<...
  • Page 50: Linking Of The Formats To The Print Functions

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 14.1 LINKING OF THE FORMATS TO THE PRINT FUNCTIONS Through function 200, combinable with the desired key (<< F.KEYS >> step, TECH.MAN.REF.), one accesses the linking of the print formats (configurable in the SEtuP >> SEriAL >> Prn.FMt step TECH.MAN.REF.) to the 30 programmable print functions: Print function Linked format...
  • Page 51: Quick Linking Of A Specific Print Function

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U TO LINK THE FORMAT:  Recall function 200, combinable with the desired key (<< F.KEYS >> step, TECH.MAN.REF.). S.F. 01  The LCD display shows: in which: XX indicates the number of the function (from 01 onwards) to which the print format is linked. ...
  • Page 52: Repetition Of The Last Executed Printout

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 14.3 REPETITION OF THE LAST EXECUTED PRINTOUT By pressing in sequence the 2ndF and F5 keys the last executed printout is repeated; the printout can be repeated many times, until a new printout is executed. 14.4 DEFAULT PRINTING FORMATS The SEtuP >>...
  • Page 53 3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U PRINT FORMULA PRODUCTION PROGRAM START PRODUCTION ----------------------- 10/05/10 - 16:58:15 ----------------------- 10/05/10 FORMULA REPORT 000 FORM. 00 1.000kg FORMULA 00 001 FORM. 01 1.000kg MIN. TARE 0.000kg MAX. TARE 0.000kg ----------------------- TOTAL 2.000kg ----------------------- TARGET 1.000kg...
  • Page 54: Other Functions

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 15. OTHER FUNCTIONS 15.1 CALCULATOR Through function 115 combinable with the desired key (<< F.KEYS >> step, TECH.MAN.REF.), one enables the calculator function.  ADDITION  MULTIPLICATION  SUBTRACTION Procedure: Enter the first value using the numerical keyboard. Press F1 to add, F2 to multiply, F3 to subtract the value.
  • Page 55: Com Data Diagnostic

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U for CPWE/CPWETF and 3590E version (with expansion board) A.O. 10.000 kg STATUS DESCRIPTION ANALOGIC OUTPUT(A.O) Analogic output value express in percent. OUTPUTS (OUT) Status output, non active ( ) or active ( INPUTS (IN) Status input, non active ( ) or active ( ).
  • Page 56: Functions Of The Output

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 16. FUNCTIONS OF THE OUTPUT 16.1 SET-POINT The indicator is supplied with 4 outputs (optional) that can be used for different functions, besides, through the I/O expansion board (optional) it is possible to use another 12. In the SEtuP >>outPut >>...
  • Page 57: Alarm / Reports

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U - SETPOINT ON THE NET WEIGHT: By selecting this functioning mode the output function on the NET weight is enabled; the entry of the SETPOINTS and the specifications are the same as the functioning mode on the gross weight. 16.2 ALARM / REPORTS DOSAGE ACTIVE: Active in the dosage cycle.
  • Page 58: Dosage On Scale

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U 16.3 DOSAGE ON SCALE ACTIVE DOSAGE SCALE 1: Active during the dosage cycle, in scale 1 ACTIVE DOSAGE SCALE 2: Active during the dosage cycle, in scale 2 ACTIVE DOSAGE SCALE 3: Active during the dosage cycle, in scale 3 ACTIVE DOSAGE SCALE 4: Active during the dosage cycle, in scale 4 TOTAL UNLOADING / FILLING SCALE 1:...
  • Page 59: Declaration Of Conformity

    3590EXP, 3590EXT, CPWE, CPWET series indicator E-BATCH1_01_13.05_EN_U DECLARATION OF CONFORMITY This device conforms to the essential standards and norms relative to the applicable European regulations. The Declaration of conformity is available in the www.diniargeo.com web site. WARRANTY The TWO-YEAR warranty period begins on the day the instrument is delivered. It includes spare parts and labour for repairs at no charge if the INSTRUMENTS ARE RETURNED prepaid to the DEALER’S PLACE OF BUSINESS.