Fujitsu FLM 150 ADM Maintenance And Trouble Clearing page 95

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
Step 6
Repeat trouble analysis procedures (See Section 2, Plug-In Unit Front-Panel
Devices). Is the PWR LED green?
If Yes:
Go to Step 7.
Connect the DMM leads to the MAIN and G test jacks on the unit. Is the MAIN
Step 7
reading between –42 and –56 V dc?
If Yes:
Go to Step 8.
Step 8
Connect the DMM leads to the +5.4V and SG test jacks and to the –5.6V and SG
test jacks. Is the reading for the +5.4V test jack between +5.02 and +6.21 V and
for the –5.6V test jack between –5.21 and –6.44 V?
Complete your fault-reporting
documentation.
Note: The Hardware Data Record form is provided in Appendix A of the Plug-In Unit
Installation practice, FJTU-320-515-220.
You have completed this procedure.
Issue 9, May 1999
Call the Fujitsu Technical Assistance Center at
1-800-USE-FTAC (1-800-873-3822) for assistance.
Call the Fujitsu Technical Assistance Center at
1-800-USE-FTAC (1-800-873-3822) for assistance.
If Yes:
FNC and FNC Customer Use Only
4.2: Replacing the Power (PW1A) Unit
If No:
If No:
If No:
Call the Fujitsu Technical Assistance
Center at 1-800-USE-FTAC
(1-800-873-3822) for assistance.
Vol. ll, Page 480.4-3