Maintenance and Trouble Clearing
FJTU-320-515-480
5.6
Correcting Unidirectional or Bidirectional Switch
Provisioning
5.6.1
Overview
This procedure lists the steps required to correct the provisioning for the
protection switching for a fiber-optic group. Note that the engineering work order
provides the appropriate provisioning.
This task can be performed using any of the following procedures presented
below: FLEXR or TL1.
5.6.2
FLEXR Procedure
Step 1
Retrieve the direction.
a. From the Provisioning menu, choose System then choose Set Switch Lock-
In.
b. Click the unit and then click on any nonselectable unit. A dialog box opens.
c. Click Retrieve to show the current setting. The possible directional settings
are UNI (unidirectional) or BI (bidirectional). Is the facility provisioned
correctly?
Click Close.
Call the Fujitsu Technical Assistance Center at
1-800-USE-FTAC (1-800-873-3822) for assistance.
Issue 9, May 1999
5.6: Correcting Unidirectional or Bidirectional
If Yes:
FNC and FNC Customer Use Only
Switch Provisioning
If No:
Go to Step 2.
Vol. ll, Page 480.5-21