Mismount - Fujitsu FLM 150 ADM Maintenance And Trouble Clearing

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
Table 3-48: MANSW (Manual Switch of Working/Protect to Protect/Working)—
AID
Direction
Type
STS1
NA
SYNCIN
TMG,
TMOUTP,
TMGPUTS
VT1
NA
3.51

MISMOUNT

Table 3-49: MISMOUNT (Remote Alarm Indication)—Standing Condition
AID
Direction
Type
EQPT
NA
Issue 9, May 1999
Standing Condition (cont'd)
Probable Cause
OPR-PROTNSW-STS1:
TID:AIDs:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
OPR-SYNCNSW
:TID:AID:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
OPR-PROTNSW-VT1:
TID:AIDs:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
Probable Cause
The unit in the slot specified is
mismounted. The plug-in unit
does not match the provisioning
for the slot.
FNC and FNC Customer Use Only
Suggested Corrective Action
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
Execute the RLS-PROTNSW-STS1 command.
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
Execute the RLS-SYNCSW command.
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
Execute the RLS-PROTNSW-VT1 command.
Suggested Corrective Action
• Verify that the correct card type is
installed.
• Check the slot provisioning and correct if
necessary.
3.51: MISMOUNT
Vol. ll, Page 480.3-31