Maintenance and Trouble Clearing
FJTU-320-515-480
Table 3-48: MANSW (Manual Switch of Working/Protect to Protect/Working)—
AID
Direction
Type
STS1
NA
SYNCIN
TMG,
TMOUTP,
TMGPUTS
VT1
NA
3.51
MISMOUNT
Table 3-49: MISMOUNT (Remote Alarm Indication)—Standing Condition
AID
Direction
Type
EQPT
NA
Issue 9, May 1999
Standing Condition (cont'd)
Probable Cause
OPR-PROTNSW-STS1:
TID:AIDs:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
OPR-SYNCNSW
:TID:AID:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
OPR-PROTNSW-VT1:
TID:AIDs:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
Probable Cause
The unit in the slot specified is
mismounted. The plug-in unit
does not match the provisioning
for the slot.
FNC and FNC Customer Use Only
Suggested Corrective Action
•
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
•
Execute the RLS-PROTNSW-STS1 command.
•
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
•
Execute the RLS-SYNCSW command.
•
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
•
Execute the RLS-PROTNSW-VT1 command.
Suggested Corrective Action
• Verify that the correct card type is
installed.
• Check the slot provisioning and correct if
necessary.
3.51: MISMOUNT
Vol. ll, Page 480.3-31