7.6 Dual-channel Two-hand Monitoring with Automatic Start

Achievable safety rating
Stop category
Features
Safety sensor/operating
mechanism
Notes
Note: All example applications shown are proposals without warranty. In any case the operator has
to perform a safety review of the entire site.
If one or both switches of the 2-hand switch are released, the EP-19xx switches off the 24-V supply
for the modules (switchable modules refer to the section, General Contact Information) inside the
safety segment and thus also for contactors K3 and K4. The failure of a switching element in the two-
hand switch or a cross-circuit in its supply lines does not result in the failure of the emergency stop
mechanism and is
detected within the fault-reaction time. An interruption of the NC contact by S2 is detected before the
next switching cycle and by S1 when the power is switched on.
The EP-19xx module switches on the 24-V supply for the following modules within the safety
segment if:
Two-hand switch is pressed synchronously within 0,5 seconds
Feedback circuit (NC contacts of K3 and K4) is closed
Contactors K3 and K4 are controlled by the PLC and can switch on as soon as the EP-19xx has
switched on the 24-V supply. To reset the system, press the reset button within 0.1 to 2 sec after
switching on the power supply, even when automatic reset is used.
GFK-2956A
Cat. 4
DIN EN ISO 13849-1
PLe
DIN EN ISO 13849-1
SIL3
IEC 62061/61508
0
EN 60204-1
• Dual-channel monitoring
• Cross-connection detection
• Automatic reset
• Monitoring of external contactors (EDM)
Two-hand switch
The application must be compatible with
the automatic start-up function.
November 2017
Chapter 7. Example Applications
51