8.52 M77, version without component support plates and without additional control components

8.52
M77, version without component support plates and without
additional control components
Availability of option
This option is available for the following S120 Cabinet Modules:
● Booksize Cabinet Kits
Description
If electronic components (Control Unit, terminal module, Sensor Module) are not used in the
Booksize Cabinet Kit, the mechanical component support plates are omitted with option
M77.
When option L08/L09 is used (motor reactor / 2 motor reactors in series), the motor cables
are connected directly to the motor reactor.
The motor cables are connected directly to the Booksize Motor Module.
Table 8- 76
Order number
6SL3720-
2TE13-0AB0
2TE15-0AB0
2TE21-0AB0
2TE21-8AB0
1TE13-0AB0
1TE15-0AB0
1TE21-0AB0
1TE21-8AB0
1TE23-0AB0
1TE24-5AB0
1TE26-0AB0
1TE28-5AB0
1TE31-3AB0
1TE32-8AB0
540
Conductor cross-section when connecting motor cables directly to the Booksize Motor
Module
Power in kW
2 x 1.6
2 x 2.7
2 x 4.8
2 x 9.7
1.6
2.7
4.8
9.7
16
24
32
46
71
107
Connection cross-section
1.5 ... 6 mm²
1.5 ... 6 mm²
1.5 ... 6 mm²
1.5 ... 6 mm²
1.5 ... 6 mm²
1.5 ... 6 mm²
1.5 ... 6 mm²
1.5 ... 6 mm²
1.5 ... 6 mm²
6 ... 50 mm²
6 ... 50 mm²
16 ... 120 mm²
25 ... 120 mm²
25 ... 120 mm²