Electrical Description And Interfaces; Fig. 9-2 Front View Of Western Plug 6-6 (Male) - Siemens M20 Terminal Technical Description

Cellular engine
Hide thumbs Also See for M20 Terminal:
Table of Contents

Advertisement

Siemens Information and Communication Products
9.1.2
Mechanical characteristics
Weight
Dimensions (max)
Temperature range
Protection class
Mechanical vibrations
Max. pulse-acceleration
Air humidity
Note: the M20 Terminal shall not be used within wet environment, such as showers, bath.
9.2

Electrical description and interfaces

M20 Terminal has following plugs for power supply, interfacing and antenna:
• 6-pole Western plug (female) for power supply, ignition signal and audio-line-in/out-signal
• 4-pole Western plug (female) for connecting a handset
• 9-pole (female) SUB-D plug for V.24/V.28 serial interface
• 20 cm antenna cable with FME plug (female)
6-pole Western plug (female)//power supply, ignition, line-in/out
Pin
1
2
3
(This Pin must not exceed Voltages >2V
to avoid power switched off!)
4
Ignition > 5V for longer than 1 s switches
on
5
(This Pin must not exceed Voltages >2V
during power on procedure to avoid a
change to bootmode!)
6
Note:
(1) Ignition signal has to be set > 5V for longer than 1 s, remember that this signal has to be low when switching off the
M20 with AT command AT^SMSO, see Chapter
(2) SW-DOWNLOAD: To switch the M20T to bootmode use the following procedure:
Apply > 8V to Pin 5 before or together with the supply voltage. The M20T switches to bootmode. Proceed according to
capt.8.5 (e.a.?) loading the SW using the RS 232-interface (9-pole SUB-D plug).
(3) POWER_OFF EXCEPTION HANDLING: In case of software hang-ups etc. the M20T can be switched off using the
following procedure (exception handling): Pin 3 must be applied with a voltage > 8V AND Pin 4 must be low (0V). To
switch on again, set ignition >5V (and Pin 2 <2V).
Fig. 9-2
Front view of Western plug 6-6 (male)
Version 8 dated 15.03.00
145 g
LxWxH = 107.0 x 63.5 x 31.3 mm
-20°C - 55 °C
IP40 (see Notice)
Amplitude 7.5 mm at 5-200 Hz sinus
30g pulse with 18 ms duration time
5–98%
Usage
Power supply 8-28.8 V
Audio Line Ground (for pin 3/AC:in & pin 5/AC:out)
AC: Line-in input 600 Ohm
DC: Signal for power Off, power off for U (to pin6) >8V (ignition
low)
Ignition signal (see M20: 80-pole connector Pin 8)
Ignition for U (to pin 6) >5V
AC: Line-out 600 Ohm
DC: Signal for initialisation of SW download for U(to Pin6)>8V
GND
5.7 "Siemens-defined AT commands for enhanced functions" on page 111
M20 Terminal
.
A
203

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents