Reset: Deadlock handling
The following sequence describes the method to reset the M20 in case there it no longer reacts to AT-commands. Cutting
the power supply is not necessary.
Shutting down must be done in two steps:
IGNITION (PIN 8 on the 80pole SMD connector) must be set to TTL-low(<0.8V)
POWER_ON (PIN 74 on the 80pole SMD connector) must be set to TTL-LOW. (see Fig. For circuit example)
8.9

Service information

In the event of M20 malfunction, please contact your distributor. For a list of distributors, see
Version 8 dated 15.03.00
POWER_ON (Pin 74)
1..4,7kOhm
This is a sure method to power
down the M20 without causing
any faults or errors. Even if the
IGNITION is accidentally left on
M20
HIGH, no damage is caused to the
unit.