Siemens SINUMERIK 840D sl Function Manual page 316

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data Description
8.3 Interface signals
SGE test stop selection
This signal is used to initiate the shutdown path test for the drive monitoring chan-
nel (see Subsection 6.1.1 "Shutdown paths").
SGE
Test
selection
Operation
"test
running"
Operation
"cancel pulses"
SGA
"status, pulses are deleted"
1
2
3
Fig. 8-1
The test stop is also carried-out at the same time in the NCK monitoring channel
(see Subsection 6.1.2 "Testing the shutdown paths").
Test stop for external STOPs
See Subsection 6.3.8 "Forced checking procedure of the external STOPs".
SGE de-select ext. STOP A
"Pulse cancellation" can be requested and executed using this SGE.
The safe functions currently active (SG/SBH/SN/SE) are not influenced by this
SGE.
If one of the currently active limits is violated, an appropriate alarm is triggered.
The associated shutdown response cannot be activated because the pulses have
already been cancelled. As soon as the stop request is cancelled via the SGE "de-
select ext. STOP A" any queued shutdown responses become active.
If a stop request is active, SGA "STOP A/B is active" is set in the same way as it
would be for an internally triggered STOP A.
0 signal:
1 signal:
8-316
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
1
stop
Timer and check
stop
Pulse cancellation is started by setting the signal (1 PLC cycle).
After the test stop has been started, a timer runs. When the time in the timer has expired,
the test stop execution is checked using the SGA "status, pulses are cancelled".
The system resets the signals.
Signal timing for SGE test stop selection
"Pulse cancellation" is requested
"Pulse cancellation" is not requested
2
3
© Siemens AG, 2006. All rights reserved
03.06