Installation Instructions
and User Guide
Infrared Automatic Basin
Spouts
Models covered: IRBS1-CP, IRBS2-CP &
IRWS1-CP
Please keep this booklet for future
reference.
Installer, when you have read these
instructions please ensure you leave them
with the user.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IRBS1-CP and is the answer not in the manual?

Questions and answers

Summary of Contents for Bristan IRBS1-CP

  • Page 1 Installation Instructions and User Guide Infrared Automatic Basin Spouts Models covered: IRBS1-CP, IRBS2-CP & IRWS1-CP Please keep this booklet for future reference. Installer, when you have read these instructions please ensure you leave them with the user.
  • Page 2: Table Of Contents

    All products manufactured and supplied by Bristan are safe and comply to legislative requirements. Providing they are installed correctly and receive regular maintenance in accordance with these instructions your user experience will not be affected.
  • Page 3: Important Safety Information

    Important Safety Information • Please read these instructions thoroughly and retain for future use. • All products manufactured and supplied by Bristan are safe provided they are installed, used correctly and receive regular maintenance in accordance with these instructions. • If you are in any doubt about your ability to install this product safely you must employ the services of an experienced qualifi...
  • Page 4: General Information

    General Information Operating pressure range: Minimum 1.0 bar, Maximum 5.0 bar. Maximum static pressure: 10.0 bar. This product has been tested to meet the requirements of the Water Regulations Advisory Scheme (WRAS) and satisfi es the requirements of the Water Supply (Water Fittings) Regulations 1999 and current byelaws.
  • Page 5: Product Features

    The water will automatically stop after a maximum of 55 seconds ± 5 seconds to avoid wasting water. If more water is IRBS1-CP required wait 4 seconds and then place hands back in the sensing range. Sensor...
  • Page 6: Specifi Cations

    Specifi cations Specifi cations Power Supply Box Inlet Connection: G1/2. Power Supply Box Outlet Connection: G1/2” Operating Pressure Range: Min. 1.0 Bar - Max. 5.0 Bar Maximum Static Pressure: 10 Bar Inlet Water Supply Temperature Range: 5ºC - 45ºC Power Supply: AC: 220V-240V; 50/60HZ DC: 6V (4 x AA alkaline batteries - Not Supplied) Power Consumption: Static <0.3MW Active: <3W...
  • Page 7: Dimensions

    Dimensions (mm) IRBS1-CP IRBS2-CP Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
  • Page 8 Dimensions Cont. IRWS1-CP Power Supply Box IRBS1-CP & IRBS2-CP IRWS1-CP G1/2 G1/2 Ø8 G1/2 Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
  • Page 9: Installation Requirements

    If the supply cord is damaged, it must be replaced by a genuine Bristan supply cord. The wire which is coloured blue must Contact Bristan Customer Services on be connected to the terminal which is 0844 701 6273 to request new spare parts.
  • Page 10: Installation

    Installation - IRBS1-CP 1. Fit The Spout Fit the spout to the sink / work surface ensuring the sensor cable is threaded through the hole in the sink / work surface. Important: It is advised to ensure that the product is at least 360mm away from refl...
  • Page 11: Irbs2-Cp

    Installation - IRBS2-CP 1. Fit The Spout Screw the fi xing rods into the bottom of the spout. Fit the spout to the sink / work surface ensuring the sensor cable is threaded through the hole in the sink / work surface.
  • Page 12: Irws1-Cp

    Installation - IRWS1-CP 1. Fit The Spout Create a 27-30mm hole in the wall surface. Thread the sensor cable and hose through the hole along with the threaded tail. Important: It is advised to install the spout to a partition / false wall to ensure access is available for future maintenance.
  • Page 13: Inserting Batteries

    Installation - Inserting Batteries Inserting Batteries Your infrared spout is supplied with a back up battery pack. In the event of a power failure the batteries will override the mains power supply to ensure the spout continues to function. Before fi tting the power supply box into position on the wall / fl...
  • Page 14: Electrical Connections

    Installation - Electrical Connections 1. Position Power Supply Box Position the power supply box onto the wall surface below the sink / work surface where it is easily accessible. Note: Ensure that the power supply box is fi tted the correct way up (see opposite) This way up and that the fl...
  • Page 15: Water Connections

    Outlet Connection IRWS1-CP IRBS1-CP & IRBS2-CP The outlet connection on both the IRBS1-CP and IRBS2-CP is a standard 1/2” BSP male threaded connection. Connect the fl exi hose (supplied) to the outlet connection, ensuring it is tightened fully.
  • Page 16 Installation - Water Connections Flexible Connecting Hose Care must be taken when connecting the See below for recommended ways to fi t fl exible connection hose from the power the fl exible connecting hose. supply box to the spout to ensure it does not bend sharply and kink or twist.
  • Page 17: Operation

    Operation Using the Automatic Basin Spout Place the users hands under the spout within the sensing range. Once the users hands have been detected water will fl ow constantly until the hands are removed. After 55 ± 5 seconds the water will stop fl...
  • Page 18: Maintenance

    & kitchen products. Using just water, E-cloth gives a smear free, deep clean by breaking up and holding dirt, which normal cloths leave behind. Order through your Bristan stockist (order code: ECLOTH). Inlet Filter Inlet water supply...
  • Page 19 Maintenance For more information about where you Disposal and Recycling can drop off your waste End of Product Life equipment for recycling, please contact When this appliance has reached the end your local council office, your household of its serviceable life, it should be waste disposal service or the shop where disposed of in a safe manner, in you purchased the product.
  • Page 20: Troubleshooting

    Water supply not turned on. Turn on water supply and open any isolation / service valves. Solenoid valve not opening. Contact Bristan Customer Services on 0844 701 6273. No mains electrical power to Connect power supply cable. the power supply box.
  • Page 21 Ensure the sensing range is randomly clear. without a user present. Sensor light faulty. Sensor light not Contact Bristan Customer working. Services on 0844 701 6273. Circuit board faulty or has been Contact Bristan Customer allowed to get wet. Services on 0844 701 6273.
  • Page 22: Guarantee

    Guarantee At Bristan, we want to make things as • Repair under this guarantee does not easy as possible for our customers. extend the original expiry date. The That’s why we design products that are guarantee on any replacement parts or easy to fi...
  • Page 23 Spare parts If this product does not function correctly We hold thousands of spares and we keep when fi rst used, contact Bristan Care them for discontinued products for over Customer Service on 0844 701 6273 seven years. Spares can easily be ordered where our expert team of advisors will be online at www.bristan.com and are...
  • Page 24 Part Number: FI Infrared Spouts Issue: D2 Useful contact details: Customer Service: 0844 7016273 Bristan Group Ltd. Customer Service Email: Birch Coppice Business Park Customercare@bristan.com Dordon Tamworth Customer Service Fax: Staffordshire 0844 7016275 B78 1SG Reception: Web: www.bristan.com 0844 7016274 Email: enquire@bristan.com...