Installation Instructions and User Guide Thermostatic Power Shower 1500 Please keep this booklet for future reference. Installer, when you have read these instructions please ensure you leave them with the user.
Contents Important safety information ..........3 Product features ..............4 Electrical requirements ............5 Water requirements ............6 Fitting your shower ..............7 Fitting the riser rail .............9 Commissioning - testing the system ........11 Operating the shower ............12 Adjusting the showerhead ..........12 Cleaning & maintenance .............12 Troubleshooting ..............13 Spare parts ................14 Guarantee ................15...
• Always switch off the power at • All products manufactured and the consumer unit and remove the supplied by Bristan are safe provided correct circuit fuse before making any they are installed, used correctly electrical connections or if you have to and receive regular maintenance in remove the cover of an installed unit.
Product Features 1. Push Button STOP/START Switch Electronic switch 2. Temperature Control Adjustable Temperature Control 3. Eco Button Non-powered shower 4. Hose outlet Shower hose outlet Removing cover 1. Temperature Control handle 2. Graphic Ring 3. Logo 4. Screws (x3) Please note that this product comes packaged with the front cover and control knobs already in place.
Electrical Requirements Warning: This appliance MUST be earthed! All electrical wiring for the shower must comply with the current I.E.E. Regulations which includes earth-cross bonding to all metal pipe work. Important: All plumbing connections should be completed before any electrical connections are undertaken.
For correct operation of the Bristan Thermostatic Power Shower both hot and cold supplies to the unit must be gravity fed, at nominally equal pressures, from a cold water storage tank and hot water storage cylinder.
Fitting your Shower Fitting the Shower Pipe entry grommet Remove center portion (15mm) We recommend that the shower unit is fitted at chest height, and set to one side of the intended riser rail position, ensuring that the top of the shower unit is at least 1 metre below the base of the cold water storage tank.
Page 8
Fitting your Shower Fit the shower unit over the pipe work, and insert the mains wiring through the aperture at the top of the base moulding. Ensure that the supply pipes are fully inserted into the mixer valve ‘push fit’ connections, and fix to the wall.
Fitting the Riser Rail 1. Mark the position Wall bracket Position the assembled riser rail on the wall, bearing in mind the different heights of people likely to use the shower and the length of the hose when connected to the shower. With the riser rail vertical, mark the wall bracket positions onto the wall.
Page 10
Fitting your Riser Rail 3.Insert rail clamps Insert the rail clamps into both wall brackets, ensuring the screw is accessable . 4. Insert riser rail Push the riser rail up through the bottom wall bracket. Rail clamp Push the soap dish and slider down onto the riser, ensuring they are the correct way up.
Commissioning - Testing the System Connect the shower hose to the unit but do not fit the handset. Turn on the hot and cold isolating valves, and the electricity- isolating switch. Place the open end of the hose in the bath or shower tray.
Operating the Shower To operate the shower ensure the temperature control knob (1) is set approximately to the 12 o’clock position and press the Stop / Start button (2). Adjust the shower temperature by turning the knob anti-clockwise - towards red, for warmer temperature, and clockwise - blue, for cooler.
Troubleshooting Warning: Before carrying out general repairs or testing the shower, ensure that the electricity supply is turned off at the mains and the correct circuit fuse is removed. Symptom Likely Cause Action/Remedy Shower not operating Electric is not switched on Check all fuses and electrical supply.
Spare Parts 1 Parts (2-12) Part No. Description No. Off SP-087-0105-WT Base assembly COV SP-087-0507 W Front cover SP-087-0505-WT Temperature control knob SP-087-0503-WT Stop/start button SP-087-0504-WT Shower Eco button SP-490-0014 Front cover screws SP-087-0230 Solenoid SP-087-0127 Pipe connection SP-087-0110 Pump unit SP-086-0060 Long Inlet Elbow SP-087-0091...
The registration of your charges for parts and labour. Charges will also be levied on personal details is purely for Bristan use and the remaining cancelled appointments, unless advised to Bristan at least information helps us to make products for the future.