Important Safety Information • Please read these instructions thoroughly and retain for future use. • All products manufactured and supplied by Bristan are safe provided they are installed correctly, used correctly and receive regular maintenance in accordance with these instructions.
Page 6
Installation cont. 3 Hole Basin Mixer & Bath Filler 9. Valve 1. Spout 10. Washer & Backnut 2. Anti- splash Assembly 11. Side Body Threaded Tail 3. Spout Threaded Tail 12. Hot Tap Body Assembly 4. T-Joint Assembly 13. Cold Tap Body Assembly 5.
Page 7
Installation cont. 3 Hole Basin Mixer & Bath Filler 1. Identify all components are present prior to starting installation. 2. Unscrew the plinth (6) from threaded tail (11) to remove the handle (4). 3. Fit the side body threaded tails (11) to the underside of the basin and secure in place by screwing the plinth (6) and handle (5) back on to the threaded tails (11), and tighten the backnuts (10).
Page 9
Installation Cont. 5 Hole Bath Shower Mixer 1. Identify all components are present prior to starting installation. 2. Remove the handles (3) from the side bodies (17 & 18) by removing the cap (4) and loosening the grub screw (4) at the rear of the handle (3) 3.
E-cloth gives a smear free, deep clean by breaking up and holding dirt, which normal cloths leave behind. Order through your Bristan stockist (order code: ECLOTH). We advise that your fitting is regularly serviced in hard water areas to maintain optimum performance.
Page 11
Backnut 5. If necessary replace the valve. Please visit www.bristan.com/sparesfinder in order to find spare parts for this product. Side body 6. Place the valve back into the tap side body and tighten the valve fully using a suitable spanner.
Page 12
4. Clean the cartridge thoroughly under cold water to remove any build up of limescale or debris. Body Please visit www.bristan.com/sparesfinder in order to find spare parts for this product. 4. Replace the cartridge into the body and tighten the retaining nut to secure in place.
Troubleshooting Symptom Cause Remedy No flow or poor flow Partially closed stop or service Open stop or service valve. rate. valve in water supply pipework to the tap. Head of water is below the Refer to the Specification section minimum distance required. for minimum pressures required.
Bristan Guarantee At Bristan, we want to make things as easy • Repair under this guarantee does not extend as possible for our customers. That’s why the original expiry date. The guarantee on we design products that are easy to fit and...
Page 15
If we can’t solve the problem over the ‘phone or with a spare part, then we’ll send •Problems during the guarantee period out one of our Bristan Care engineers to In the unlikely event that you encounter any take a look. Bristan Care engineers provide...
Page 16
HOU 1HBF C HOU 3HBAS C HOU 3HBF C HOU 5HBSM C Helpline 0844 701 6273 Bristan Group Limited Birch Coppice Business Park, Dordon, Tamworth, Staffordshire B78 1SG A Masco Company Website: www.bristan.com Telephone: 0844 7016 274 Facsimile: 0844 701 6275 Email: enquire@bristan.com...
Need help?
Do you have a question about the Hourglass HOU 1HBF C and is the answer not in the manual?
Questions and answers