Specifications - Growatt SPF 5000 ES User Manual

Off grid solar inverter
Hide thumbs Also See for SPF 5000 ES:
Table of Contents

Advertisement

Specifications

Table 1 Line Mode Specifications
INVERTER MODEL
Input Voltage Waveform
Nominal Input Voltage
Low Loss Voltage
Low Loss Return Voltage
High Loss Voltage
High Loss Return Voltage
Max AC Input Voltage
Nominal Input Frequency
Low Loss Frequency
Low Loss Return Frequency
High Loss Frequency
High Loss Return Frequency
Output Short Circuit Protection
Efficiency (Line Mode)
Transfer Time
Output power derating:
When AC input voltage drops to 170V,
the output power will be derated.
SPF 5000 ES
Sinusoidal (utility or generator)
170Vac± 7V (UPS); 90Vac± 7V (Appliances)
180Vac± 7V (UPS); 100Vac± 7V (Appliances)
50Hz / 60Hz (Auto detection)
Circuit Breaker
>95% ( Rated R load, battery full charged )
<20ms @ Single
<30ms @ Parallel
Output Power
Rated Power
20% Power
90V
170V
37
230Vac
280Vac± 7V
270Vac± 7V
300Vac
40± 1Hz
42± 1Hz
65± 1Hz
63± 1Hz
280V
Input Voltage

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPF 5000 ES and is the answer not in the manual?

Questions and answers

Pete Gielow
April 11, 2025

spf 5000, for my input from utility, I have 2 lines of 120 and 1 neutral and ground. Do I join the 2 lines together?

1 comments:
Mr. Anderson
April 11, 2025

No, you should not connect two 120V lines together for the Growatt SPF 5000 ES inverter. For 240V loads, connect Line 1 and Line 2 directly from the inverter. Each line provides 120V relative to neutral, and together they supply 240V. Connecting two 120V lines improperly can cause damage or unsafe conditions.

This answer is automatically generated