Ethernet Network Diagnostics - Siemens SINUMERIK 840D sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Procedure
18.11.4

Ethernet network diagnostics

18.11.4.1
Diagnostics of the network and DHCP server
In order to more effectively influence the commissioning, press the "Network diagnostics"
softkey to easily represent the data and availability of each network node on the Ethernet.
The results display of this scan process delivers, among other things, the following
information:
● Component identification of the hardware
● TCP/IP address / MAC address
● DHCP server detection
● Status of the nodes
This gives you the option to test whether the current topology matches the reference
topology.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
1.
Select the "Diagnostics" operating area.
2.
Press the menu forward key and the "Bus TCP/IP" softkey.
3.
Press the "TCP/IP diagnostics" and TCP/IP Config." softkeys.
The "TCP/IP Configuration" window opens.
4.
Press the "Modify" softkey to change specific parameters.
The fields that can be edited have a white background.
5.
Enter the desired changes and press the "OK" softkey to confirm the
entries.
6.
Press the "New display" softkey to refresh the display.