Chapter 5 System Configuration; Configuration Of Laser Displacement Sensor - Mitsubishi Electric Melsec iQ-R Series User Manual

Laser displacement sensor control module for programmable controller
Hide thumbs Also See for Melsec iQ-R Series:
Table of Contents

Advertisement

5
SYSTEM CONFIGURATION
5.1

Configuration of Laser Displacement Sensor

The following figure shows the system configuration of the control module.
(1)
(1) Engineering tool, setting tool
(2) Control module
(3) Sensor head A
(4) Sensor head B
(5) External power supply
For applicable combinations of CPU modules and the other modules and for the number of mountable
modules, refer to the following.
 MELSEC iQ-R Module Configuration Manual
Precautions
• When connecting one sensor head to the control module, connect the sensor head to the SENSOR HEAD A connector.
When one sensor head is used and it is connected to the SENSOR HEAD B connector, measurement cannot be
performed.
• Be careful of the incorrect wiring when connecting each device. For the wiring, refer to the following.
Page 32 Wiring Method
(2)
(5)
(4)
(3)
5.1 Configuration of Laser Displacement Sensor
5 SYSTEM CONFIGURATION
5
27