Installing/mounting
3.3 Disassembly
3.2.3
Installation in a drop line
Installation in a drop line is only recommended if a pipeline reduction or orifice with a smaller
cross-section can be installed to create back-pressure and prevent the sensor from being
partially drained while measuring.
①
②
Figure 3-6
3.3
Disassembly
Incorrect disassembly
The following risks may result from incorrect disassembly:
- Injury through electric shock
- Risk through emerging media when connected to the process
- Risk of explosion in hazardous area
In order to disassemble correctly, observe the following:
● Before starting work, make sure that you have switched off all physical variables such as
● If the device contains hazardous media, it must be emptied prior to disassembly. Make
● Secure the remaining connections so that no damage can result if the process is started
28
Back pressure orifice
On / off valve
Installation in drop line
WARNING
pressure, temperature, electricity etc. or that they have a harmless value.
sure that no environmentally hazardous media are released.
unintentionally.
Compact Operating Instructions, 09/2019, A5E39940293-AB
SITRANS FC430