IPC6061-FP
Quick Start Guide
Figure 4-7 Alarm input
Step 2 Connect alarm output device to the alarm output port of I/O port cable.
Alarm output is relay switch output; alarm output port can only be connected to NO alarm
device. Port ALARM_OUT and ALM_OUT_GND form a switch, which is shown in
4-8, the switch is used to provide alarm output. Generally the switch is opened; the switch
will be closed when there is alarm output.
Figure 4-8 Alarm output
Step 3 Log in Web interface, make corresponding settings upon alarm input and output on the
interface of alarm setup.
l
l
----End
(Optional) Install the Waterproof Connector
The installation process of waterproof connector for network port is shown in
Issue 01 (2019-02-22)
Alarm input of Web is corresponding to the alarm input of I/O port cable. It is to set
corresponding NO, NC input according to the high and low level signal generated when
alarm happens for alarm input device.
Set alarm output on the Web, alarm output is corresponding to the alarm output end,
which is the alarm output port of the I/O port cable.
NOTE
It needs to implement the operation when the device is equipped with waterproof connector and it is
used outdoors.
Copyright © Huawei Technologies Co., Ltd.
4 Installation
Figure
Figure
4-9.