Siemens SINUMERIK 840D sl Programming Manual page 62

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Measuring variants
2.2 Measure workpiece (turning)
NOTICE
When the calibration is performed for the first time, the default setting in the data field of the
probe is still "0". For this reason, the TSA parameter must be programmed > probe ball
radius to avoid the alarm "Safe area exceeded".
List of the result parameters
The measuring variant "Radius on surface" provides the following result parameters:
Table 2- 3
Parameters
_OVR [4]
_OVR [5]
_OVR [8]
_OVR [10]
_OVR [12]
_OVR [14]
_OVR [9]
_OVR [11]
_OVR [13]
_OVR [15]
_OVR [20]
_OVR [21]
_OVR [27]
_OVR [28]
_OVI [2]
_OVI [5]
_OVI [9]
62
"Radius on surface" result parameters
Description
Actual value probe ball diameter
Difference probe ball diameter
Trigger point in minus direction, actual value of 1st axis of the plane
Trigger point in plus direction, actual value of 1st axis of the plane
Trigger point in minus direction, actual value of 2nd axis of the plane mm
Trigger point in plus direction, actual value of 2nd axis of the plane
Trigger point in minus direction, difference of 1st axis of the plane
Trigger point in plus direction, difference of 1st axis of the plane
Trigger point in minus direction, difference of 2nd axis of the plane
Trigger point in plus direction, difference of 2nd axis of the plane
Positional deviation of the 1st axis of the plane (probe skew)
Positional deviation of the 2nd axis of the plane (probe skew)
Zero offset area
Safe area
Measuring cycle number
Probe number
Alarm number
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0
Unit
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
-
-
-
Measuring cycles

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumeric 828dSinumerik 840de slSinumerik 828d

Table of Contents