84/97
Bosch Rexroth AG
Vibration Damping With Superimposed Process Loop (Process Control With Intelligent Servo Axis)
Error Handling
ErrorID
INPUT_RANGE_ERROR
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Rexroth IndraDrive Rexroth IndraMotion MLD Application Examples
The function block "MX_PID_Regler" generally is a PID loop with feedforward
function and PT1 filters for feedforward and the D-component.
By means of the tolerance window, you can set a range in which the output gets
the state "Done True" when the actuating variable is smaller than the tolerance
window.
Switching the controller off by "Enable = False" sets all internal variables and
the actuating variable to zero.
In the case of error, this function block generates a detailed diagnosis. For a
precise description of the error code which is output (Additional1, Additional2),
see the table below.
Additional1
Additional2
Description
16#0C01
16#1
Preset negative limitation is greater than positive limit
16#0C01
16#2
Kp-gain smaller than "0"
16#0C01
16#3
Integral action time smaller than sampling time or smaller than "0"
16#0C01
16#4
Derivative action time smaller than sampling time or smaller than
"0"
16#0C01
16#5
Filter time constant D-component smaller than sampling time or
smaller than "0"
16#0C01
16#6
Filter time constant feedforward smaller than sampling time or small‐
er than "0"
Fig.8-9:
ERROR_TABLE
DOK-INDRV*-MLD-APPLI**-AW02-EN-P