Hitachi AP1 Data Book page 180

4-bit single-chip microcomputer
Table of Contents

Advertisement

LCO-IV--------------------------------------------------------------------
ELECTRICAL CHARACTERISTICS - 2 (Ta
=
-20 to +75°C)
Value
Unit
Note
Item
Symbol
Test Conditions
min.
max.
Halt Duration Voltage
VDH
HLT = 0.2V
2.3
-
V
(17)
Halt Current
IDH
Vin
=
Vcc, HLT = 0.2V,
-
4.0
p.A
(17),
VDH = 2.3V
(19)
Halt Delay Time
tHD
100
-
p.s
(17)
Operation Recovery Time
tRC
100
-
p.s
(17)
HL T Fall Time
tfHLT
-
1000
p.s
(17)
H L T Rise Time
trHLT
-
1000
p.s
(17)
HL T "Low" Hold Time
tHLT
400
-
p.s
(17)
Rt Oscillation, External
100
-
H L T "High" Hold Time
tOPR
Clock Operation
p.s
(17)
Ceramic Filter Oscillation
4000
-
Rt Oscillation, External
5
-
RESET Pulse Width
(1)
tRST1
Clock Operation
ms
(18)
Ceramic Filter Oscillation
20
-
Prescaler Clock
2·Tinst
= System Clock
External
Not clear
Reset,
Prescaler
Prescaler
2·Tinst
-
p.s
(18)
RESET Pulse Width (2)
tRST2
HL T=Vcc
clock=Dlsl
with Reset
VCC = 4.5
XI clock
signal
to 5.5V
(32 x 10
6
1
Clear
foscx)
Prescaler
32 x 10
6
1
-
with Reset
f oscx
signal
RESET Rise Time
trRST
External Reset, HL T = Vcc,
-
100
p.s
(18)
Vcc = 4.5 to 5.5V
--
- - - - -
RESET Fall Time
tfRST
External Reset, HL T = Vcc,
-
100
p.s
Vcc = 4.5 to 5.5V
(NOTE)
1. Applied to PMOS load of CMOS output pins and CMOS I/O common pins among D and R terminals.
2. Applied to CMOS output pins. CMOS I/O common pins, input pins with pull up MOS, and I/O common pins with pull up
MOS among D and R terminals.
3. Applied to open-drain output pins and open-drain I/O common pins among 0 and R terminals.
4.
Pull up MOS current is excluded.
5. Applied to the supply current when the LCD·IV is in the reset state and the crystal oscillation for timer doesn't operate.
(Current that flows in the input/output circuit and in the power supply circuit for LCD·is
exclud~d).
Test Condition: RESET, HLT, TEST
=
Vee (Reset State)
INTo, INT. ,Roo to R 33 , D. to DI3
=
VCC
D •• /XO, D.s/XI-cD •• /XO, D.s/XI
=
Vee (Crystal oscillation for timer is not selected).
V., V., V3
=
Vee
D •• /XO
=
Open, DIS/XI
=
Vee (Crystal oscillation for timer is selected).
COM, to COM., SEG. to SEG 3 •
=
Open
When the crystal oscillation for timer operates, the standby supply current (2) leeS2 flows in addition to Icel or Ice2.
When the LCD·IV is installed in the user's system, and in operation current increases according to the external circuitry and
devices. Those are connected to the LCD·IV. User should design the power supply in consideration of this point (The
difference between the measured current in the above reset state and that measured in the operational state in the user's
system is the increased part of the supply current).
6. Standby I/O leakage current is the leakage current of I/O pins in the "Halt" and "Disable" state.
(18)
7.
Current that flows in the input/output circuit and in the power supply circuit for LCD is excluded. The standby supply
current (2) is the supply current at Vee
=
5V
±
10% in "Halt" state in the case that the crystal oscillation for timer is selected
(only the crystal oscillator for timer, 5·bit divider and 6-bit prescaler are in operation).
178