2

Technical data

2.1

Welding timer

1070 080 067-101 (2001.03) GB
PSI 6XXX.350 L1
Degree of protection
Operating voltage
Rated current (w/o I/Os) at 24V
Making current
Switchgear cubicle basic power
dissipation
Environmental conditions
-
Operation
-
Storage
-
Transport
-
Air pressure
-
Humidity
Number of programs
Load cell input
Load cell reset output
I/O bus
Field bus for programming
Proportional control valve
Programming with BOS-5000 via
laptop computer, Bosch BT oper-
ating terminal or INTERBUS-S
interface
Operational software
Program memory
Technical data
IP20 when installed in power unit
+24 VDC
(min. 19VDC, max. 30VDC i.a.w.
EN61131-2)
optional internal supply or external
supply to logic
approx. 1.5 A
approx. 2 A for 10 ms
approx. 70 W
0 °C to +55 °C
-25 °C
. . . .
to +70 °C
-25 °C
. . . .
to +70 °C
0 to 2000 m above sea level
No dew point excursion allowed
256, access to each individually
from spot selection
Analog input,
0 to 5V (1V equivalent to 1 kN)
+24VDC
INTERBUS-S (optical waveguide)
in combination with I/O bus
8 bits, equivalent to 0 through
10 bar
via internal V24 / RS232 interface,
isolated
Connection: 9-pin Cannon connec-
tor
in flash memory, can be loaded
through V24/RS232 or field bus
RAM memory (battery-buffered)