9.8

Activating monitoring

9.9

Other adjustments and programs

1070 080 067-101 (2001.03) GB
PSI 6XXX.350 L1
For quality assurance, Current and/or Time Monitoring should always be switched on,
and the appropriate tolerance bands should be entered.
The Actual Values are displayed and can be accepted as setpoints.
Activating monitoring
D
Select Programming - Basic-Setup - Sequence Setup.
Enter Current Monitoring and the tolerance band
D
Select Programming - Welding Parameters - Current Monitoring.
To facilitate the definition of the reference current and tolerance band, this window
shows an Actual value display.
Activate Time Monitoring
D
Select Programming - Welding Parameters - Time Monitoring.
To facilitate the definition of the reference time and the admissible time tolerance,
this window shows an Actual value display.
Program Monitor Stepper
D
Select Programming - Welding Parameters - Monitor Stepper and enter the moni-
toring values.
When commissioning has been completed, you may protect access to the BOS-5000
software in order to restrict changing the Welding Parameters and the Basic-Setup by
defining user levels. A systems disk is needed for this purpose.
Use the BOS-5000 Set-up in the System menu for this purpose.
D
Other adjustments:
Maximum admissible limits for [%I] and [Pressure] correction by the user.
D
Regulation and monitoring mode
D
Creation of spot allocation tables
D
Other programs with slightly different parameters can be generated by copying.
Copying programs:
D
Select Operation - Services - Copy.
Adjusting the Stepper Reference in the copied program.
D