Timeguard PDWM1500 Installation & Operating Instructions Manual

Timeguard PDWM1500 Installation & Operating Instructions Manual

120 degrees surface mount wall pir light controller

Advertisement

Quick Links

120° Surface Mount Wall
PIR Light Controller
Model: PDWM1500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PDWM1500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Timeguard PDWM1500

  • Page 1 120° Surface Mount Wall PIR Light Controller Model: PDWM1500...
  • Page 2: General Information

    • CE Compliant • EC Directives: Conforms to latest directives • Multiple PIR Sensor Switching: A maximum of 4 PDWM1500 PIR sensors can be wired in parallel, to enable any detector to turn ON all the lights connected (The total load must not exceed the lamp rating of a single PDWM1500 unit).
  • Page 3: Selecting A Location

    4. Selecting a Location • Careful positioning of the sensor will be required to ensure optimum performance (See diagram “A” & “B” detailing detection range and direction). • The mounting height for the sensor should be between 1m to 1.8m. •...
  • Page 4: Installation

    5. Installation • Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker turned off. • An isolating switch should be installed to enable the power to be switched ON and OFF for maintenance purposes. •...
  • Page 5: Connection Diagram

    6. Connection Diagram •Connect cables to the terminal block as follows; 230V AC 50Hz MAINS SUPPLY LOAD ISOLATION SWITCH 230V AC 50Hz Mains Supply Load Live (Brown or Red) to L Switch Live (Brown or Red) to L1 Neutral (Blue or Black) to N Neutral (Blue or Black) to N...
  • Page 6 7. Setting Up Walk Test Procedure • Turn the power to the unit ON. The lamp will immediately illuminate as the unit goes through its “warm-up” period. After approximately 1 minute the lamp will extinguish. This indicates the unit is wired correctly and the unit is in Test Mode.
  • Page 7 Setting Up for Automatic Operation • When walk tests are complete, the unit can be adjusted for automatic operation. • The TIME setting controls how long the unit remains illuminated following activation & after all motion ceases. • Use a thin flat blade screwdriver to make adjustments. •...
  • Page 8: Troubleshooting

    8. Troubleshooting Problem Solution • The lamp stays Cover PIR lens with a thick cloth. If the light turns out, ON all the time check detection area for heat or reflective source. at night. If the light stays ON, check wiring (See section 6. Connection Diagram).
  • Page 9 • The PIR sensor will The level of ambient light in the area may be too bright not operate at night to allow operation at the current DUSK setting. During the hours of darkness, adjust the DUSK control slowly clockwise until the lamp illuminates (See section 7.
  • Page 10: Year Guarantee

    020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/ postage charges outside of the UK. All shipping costs are to be paid in...
  • Page 12 If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline @ timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.