1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety • Before installation or maintenance, ensure the mains supply to the PIR sensor is switched off and the circuit supply fuses are removed or the circuit breaker turned off. •...
• Dimensions (H x W x D): 90 x 90 x 60mm • Multiple PIR Sensor Switching: A maximum of 8 SLFM360N PIR sensors can be wired in parallel, to enable any detector to turn ON all the lights connected.
Diagram A Diagram B Up to 4m Presence Detection Up to 8m Motion Detection 5. Installation • Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker turned off. • An isolating switch should be installed to enable the power to be switched ON &...
Page 5
• The adjustment knobs located beneath the sensor head are factory-set to “Test Mode” . Double check they are set as follows; • Replace both cable clamps previously removed, using the 4 cable clamp screws, to secure the mains supply and load cables to the sensor. Do not overtighten the screws.
• Push back the locating springs and feed the unit into the ceiling void via the 75mm hole. The locating springs will now fold back and hold the SLFM360N in place. 6. Connection Diagram • Connect the cables as follows;...
Page 7
7. Setting Up Walk Test (Test Mode) • Turn the power to the unit ON. The lamp will immediately illuminate as the unit goes through its “warm-up” period. After approximately 45 seconds the lamp will extinguish. This indicates the unit is wired correctly and the unit is in Test Mode.
Page 8
8. Setting Up for Automatic Operation (Auto Mode) • When the walk tests are complete, the unit can be adjusted for automatic operation. • The Time Setting controls how long the unit remains illuminated following activation and after all motion ceases. •...
10. Troubleshooting Problem Solution • The Lamp stays ON Cover the PIR lens with a thick cloth. If the all the time at night. light turns OFF, check the detection area for heat or a reflective source. If the light stays ON, check the wiring (see section 5.
Page 10
• PIR coverage is The PIR may be poorly located. See section 4. poor/sporadic Selecting a location and relocate the unit. • The detection range The PIR detectors are influenced by climatic varies from day conditions. The colder the ambient temperature, to day.