BRAND NAME
WL290
ITEM
Water Connection
Cold Water Temperature
Cold Tank and Cold‐Water
Reservoir Size
Cold‐Water Reservoir
Hot Water Temperature
Hot Tank Size
Resettable Hot Tank
Overload Devices (High
Limit Safety)
Recommended Service
Pressure
Maximum Service Pressure 100 psi (689 kPa) – Use Pressure Regulator
Rated Service Flow Out
Environmental Temperature 2° ‐ 37°C (35° ‐ 100°F)
UV Lamp
Heater
Pump
Refrigerant Gas
R134a Pressures
WL290 Manual
MODEL/PART DESIGNATIONS
DESCRIPTION
Waterlogic WL290 – Cold and Hot
F‐1010‐FS‐HC‐UT‐CS‐WLU
Serial Number Prefix ‐ 19
SPECIFICATIONS
¼" Quick Connect
Cold Water Temperature – Factory Set Point 5°C (41°F)
(Programmable) 3° ‐ 7°C (37° ‐ 45° F.)
4 Liter (1 Gallon) Cold Tank plus 11.2 Liter (3 Gallons) Cold Tank Reservoir
Total of 15.2 Liters (4 Gallons) of Ice Cold Water capacity
11.2 Liter (3 Gallons)
Hot Water Temperature – Factory Set Point 85°C (185°F)
(Adjustable) 80°C – 93°C (176° ‐ 199°F)
1.6 Liters (0.4 Gallons)
105°C (221°F)
40‐60 psi (275‐414 kPa) – Use Pressure Regulator
1.89 Liters per Minute (0.5 gallons per minute)
8 Watts
500 W
24V DC – 120 psi – Flow 1000ml/min
R134a, 58 grams, 2.05 ounces
High (230 psi), Low (90 psi)