BRAND NAME
WL100 Counter Top
WL100 Tower
ITEM
Water Connection
Cold Water Temperature
Hot Water Temperature
Hot Water Manual Reset
Overload
Recommended Service
Pressure
Maximum Service Pressure 100 psi (689 kPa) – Use Pressure Regulator
Rated Service Flow
Environmental Temperature 35° ‐ 100°F (2° ‐ 37°C)
Heater
Refrigerant Gas
R134a Pressures
ITEM
Width/Depth/Height
Weight (dry)
ELECTRICAL SUPPLY
COMPONENT
Heater
Compressor
WL100 TOTAL
#WL100 Counter Top is 17.75 in. tall and may not fit between countertops and cabinets ‐ Check installation to ensure adequate clearance.
WL100 Operating, Installation, and Service Manual Page 7 Revision: 5‐20‐2016
MODEL/PART DESIGNATIONS
DESCRIPTION
Waterlogic WL100 Counter Top ‐ Cold and Hot
F‐100‐M‐HC‐TT‐CS‐WLU
Waterlogic WL100 Tower ‐ Cold and Hot
F‐100‐FS‐HC‐TT‐CS‐WLU
SPECIFICATIONS
WL100 Counter Top
¼" Quick Connect
Cold Water Temperature – Factory Set Point 41° ‐ 5°C
Adjustable to 34° - 54° F. (1.1° ‐ 12.2°C)
85°C (185° F)
105°C (221° F)
40‐60 psi (275‐414 kPa) – Use Pressure Regulator
1.89 Liters per minutes (0.5 gallons per minute)
500 W
R134a, 40g, 1.41 ounces
High (230 psi), Low (90 psi)
SHIPPING SPECIFICATIONS
WL100 Counter Top
#
13.5" x 16" x 17.75"
(34cm x 41cm x
45cm)
40 pounds (18 kg)
ELECTRICAL SPECIFICATIONS
120V/60Hz, 1PH
POWER (approximate)
504
168
672
WL100 Tower
R134a, 45g, 1.59 ounces
WL100 Tower
13.5" x 16" x 40.5" (34cm x 41cm x
103cm)
50 pounds (23 kg)
15 Amp Service
AMP DRAW (approximate)
4.2 Amps
1.4 Amps
5.6 Amps
MODEL ‐
PART NUMBER
12‐CHCM
12‐CHC
Need help?