Name and Function of Each Part
■ ANUJ5014/5012 Aicure Operation Modes
The ANUJ5014/5012 Aicure has the following operation modes.
Manual Mode
On the Menu screen, touch MANUAL to operate from the Manual Mode screen.
• Press the EMISSION button on the main unit to begin irradiation. Press the EMISSION button
again to stop it. During irradiation, the EMISSION button is illuminated.
• In Manual Mode, all inverted-display (LED connected/selected) LEDs shine at once.
• During irradiation, the modulation ratio can be adjusted.
Warning
When the light modulation ratio is 0%, no irradiation will be performed.
Auto Batch Pulse Start Mode (Initial Setting)
On the Menu screen, ensure that ALL/Pulse are inverted. Touch Auto to operate from the Auto Mode
screen.
• When the main unit is in READY status, the external START 1 signal initiates batch irradiation of
the LEDs selected for this model.
• When the main unit is in READY status, pressing the EMISSION button on the main unit initiates
batch irradiation of the LEDs selected for this model.
Warning
• If any of the LEDs to be used for irradiation are currently irradiating (NO LED status), irradiation
will not begin.
• Emergency stop during irradiation can be achieved via setting the emergency stop signal on the
main unit to "open" (normally "closed"), when the external STOP 1 signal is turned on, or when
the EMISSION button on the main unit is on.
Auto Individual Pulse Start Mode
On the Menu screen, select MULTI/ Pulse, and touch Auto to operate from the Auto Mode screen.
• When the main unit is in READY status, the external Start signals initiate individual irradiation of
the LEDs selected for this model.
• When the main unit is in READY status, pressing the EMISSION button on the main unit initiates
batch irradiation of the LEDs selected for this model.
Warning
• If an LED to be used for irradiation is currently irradiating, irradiation will not begin. (Irradiation of
other LEDs is possible.)
• Emergency stop during irradiation can be achieved via setting the emergency stop signal on the
main unit to "open" (normally "closed"), when the external START or STOP signal number
corresponding to the irradiating LED is turned on, or when the EMISSION button on the main unit
is on.