Setting The Device Name (Nameofstation) Of An Io Device On Profinet Io - Siemens SIMOTION Function Manual

Motion control basic functions for modular machines
Hide thumbs Also See for SIMOTION:
Table of Contents

Advertisement

Setting the communication addresses via the user program

4.3 Setting the device name (NameOfStation) of an IO device on PROFINET IO

Figure 4-2
Example of a topology in PROFINET IO
Table 4-1
Topology detection at
SIMOTION_1 (Port 1)
SIMOTION_1 (Port 4)
SIMOTION_2 (Port 1)
SIMOTION_2 (Port 4)
SIMOTION_3 (Port 1)
SIMOTION_3 (Port 3)
4.3
Setting the device name (NameOfStation) of an IO device on
PROFINET IO
The user program can change and activate the device name (NameOfStation) for the
SIMOTION device on the PROFINET IO using system functions. The activation results in a
restart of SIMOTION.
Note
After changing the configured device name (NameOfStation), the following should be noted:
● It is no longer possible to route via this interface into other devices or interfaces (see
● Controller-controller data exchange broadcast is no longer possible.
If these functionalities are still required, follow Activating a configuration (Page 89) instead.
46
Topology detection (call up of the _getPnPortNeighbour or _getPnInterfacePortNeighbour
function) for the topology example in the previous figure
device (port)
Routing in the communication network in the section titled System behavior (Page 43)).
Result of the topology detection (components of the return value)
nameOfStation
' '
'pn-switch.n1'
'pn-switch.n1'
'device.n3'
' '
'device.n2'
pnPortNumber
-1
1
2
3
-1
4
Basic Functions for Modular Machines
Function Manual, 04/2014
pnSlotNumber
-1
0
1
-1
-1
-1

Advertisement