GETTING STARTED GUIDE
PXIe-4163
PXIe, 24-Channel, ±24 V, 50 mA PXI Source Measure Unit
This document explains how to install, configure, and test the PXIe-4163. The PXIe-4163
ships with NI-DCPower driver software, which you can use to program the module.
Note
Before you begin, install and configure your chassis and controller.
Contents
Verifying the System Requirements..........................................................................................1
Unpacking the Kit..................................................................................................................... 1
Other Equipment....................................................................................................................... 3
Preparing the Environment....................................................................................................... 3
Installing the Software.............................................................................................................. 4
Installing the PXIe-4163........................................................................................................... 4
PXIe-4163 Pinout and LEDs.....................................................................................................6
Configuring the PXIe-4163 in MAX...................................................................................... 13
Self-Calibrating the PXIe-4163.............................................................................................. 14
Programming the PXIe-4163.................................................................................................. 15
Troubleshooting...................................................................................................................... 17
What Should I Do if the PXIe-4163 Doesn't Appear in MAX?......................................17
Why Is the ACCESS LED Off When the Chassis Is On?...............................................18
What Should I Do if the PXIe-4163 Fails the Self-Test?................................................18
Where To Go Next.................................................................................................................. 19
Worldwide Support and Services............................................................................................ 19

Verifying the System Requirements

To use the NI-DCPower instrument driver, your system must meet certain requirements.
Refer to the product readme, which is available on the driver software media or online at
ni.com/manuals, for more information about minimum system requirements, recommended
system, and supported application development environments (ADEs).

Unpacking the Kit

Refer to the following figure to identify the contents of the PXIe-4163 kit.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXIe-4163 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments PXIe-4163

  • Page 1: Table Of Contents

    GETTING STARTED GUIDE PXIe-4163 PXIe, 24-Channel, ±24 V, 50 mA PXI Source Measure Unit This document explains how to install, configure, and test the PXIe-4163. The PXIe-4163 ships with NI-DCPower driver software, which you can use to program the module. Note Before you begin, install and configure your chassis and controller.
  • Page 2 Do not install a module if it appears damaged in any way. Unpack any other items and documentation from the kit. Store the module in the antistatic package when the module is not in use. 2 | ni.com | PXIe-4163 Getting Started Guide...
  • Page 3: Other Equipment

    Other Equipment There are several required items not included in your PXIe-4163 kit that you need to operate the PXIe-4163. Your application may require additional items not included in your kit to install or operate your PXIe-4163. Required Items •...
  • Page 4: Installing The Software

    To prevent damage to the PXIe-4163 caused by ESD or contamination, handle the module using the edges or the metal bracket. The PXIe-4163 is a single-slot module with one backplane connector. The module may be installed into any PXI Express-compatible slot.
  • Page 5 5. PXI Express Peripheral Slot 3. PXI Express Hybrid Peripheral Slot PXIe-4163 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. Touch any metal part of the chassis to discharge static electricity.
  • Page 6: Pxie-4163 Pinout And Leds

    Why Is the ACCESS LED Off When the Chassis Is On? on page 18 PXIe-4163 Pinout and LEDs Front Panel Refer to the following figures and tables for information about the PXIe-4163 front panel connector pins, channels, and LEDs. PXIe-4163 24-CH Precision SMU...
  • Page 7 Refer to the driver software for possible sources. The device will not operate until the error is cleared and/or the device is reset. Pinout The following figure and table provide detailed signal information for the PXIe-4163 connector. PXIe-4163 Getting Started Guide | © National Instruments | 7...
  • Page 8 CH20 Output HI CH19 Sense HI CH18 Sense HI CH20 Sense HI CH18 23 Sense LO CH23 Output HI CH21 Output HI CH22 Output HI CH23 Sense HI CH21 Sense HI CH22 Sense HI 8 | ni.com | PXIe-4163 Getting Started Guide...
  • Page 9 Signal Description Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI 0 to 5 Sense LO PXIe-4163 Getting Started Guide | © National Instruments | 9...
  • Page 10 Channel Signal Description Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI 6 to 11 Sense LO 10 | ni.com | PXIe-4163 Getting Started Guide...
  • Page 11 Signal Description Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI 12 to 17 Sense LO PXIe-4163 Getting Started Guide | © National Instruments | 11...
  • Page 12 Output HI Sense HI Output HI Sense HI Output HI Sense HI Output HI 18 to 23 Sense LO A, B, C, D 0 to 23 Output LO — — Calibration HI Void 12 | ni.com | PXIe-4163 Getting Started Guide...
  • Page 13: Configuring The Pxie-4163 In Max

    Cable Bundles The PXIe-4163 has 24 channels organized into four cable bundles (A, B, C, D) for use with associated cable accessories. The following figure and table provide detailed bundle information. Channel 7 Grouping Output HI Output HI Output HI...
  • Page 14: Self-Calibrating The Pxie-4163

    • After first installing the PXIe-4163 in a chassis • After any module that is in the same chassis as the PXIe-4163 is installed, uninstalled, or moved • When the PXIe-4163 is in an environment where the ambient temperature varies or the PXIe-4163 temperature has drifted more than ±5 °C from the temperature at the last self-...
  • Page 15: Programming The Pxie-4163

    Programming the PXIe-4163 You can generate signals interactively using InstrumentStudio or you can use the NI-DCPower instrument driver to program your device in the supported ADE of your choice. PXIe-4163 Getting Started Guide | © National Instruments | 15...
  • Page 16 • From Measurement & Automation Explorer (MAX), select a device and then click Test Panels..This launches InstrumentStudio and runs a soft front panel for the device you selected. 16 | ni.com | PXIe-4163 Getting Started Guide...
  • Page 17: Troubleshooting

    Troubleshooting If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support. What Should I Do if the PXIe-4163 Doesn't Appear in MAX? In the MAX configuration tree, expand Devices and Interfaces. Expand the Chassis tree to see the list of installed hardware, and press <F5> to refresh the list.
  • Page 18: Why Is The Access Led Off When The Chassis Is On

    LED. Notice Apply external signals only while the PXIe-4163 is powered on. Applying external signals while the module is powered off may cause damage. Disconnect any signals from the module front panels.
  • Page 19: Where To Go Next

    78759-3504. NI also has offices located around the world. For support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For PXIe-4163 Getting Started Guide | © National Instruments | 19...
  • Page 20 NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the file on your media, or the National Instruments Patent Notice at . You can find patents.txt ni.com/patents...

Table of Contents